BRD (dynamic braking) function

This function only operates with the N300-11kW and lower, as they have
the built-in BRD.
This function is to consume regenerative energy from the motor as heat by
the use of an external resistor.
Regeneration occurs when the motor is decelerated to quickly and the motor turns into a generator and voltage
flows back into the inverter.
To use the BRD function, set following condition.
Set item
Function
code
BRD usage
Ratio
b090
Selection of
b095
BRD
b096
BRD ON Level
(Note 1) BRD ON level is the voltage setting of the DC (direct current) voltage of the inverter.

Cooling fan operating selection

You can select whether the fan operates continuously or operates only when the
inverter is in the running operation.
Function
data
code
00
b092
01
Data
0.0
BRD don't operate.
The usage ratio of BRD is set by 0.1% unit
When inverter exceeds the usage ratio, trip.
BRD action
0.1-100.0
00
BRD don't operate.
During run : valid (BRD operates.)
01
During stop : invalid (BRD desn't operate.)
During run, stop, valid (Brd operates.)
02
(Note 1)
Unit : V In case of 200V class inverter, setting is valid.
330-380
(Note 1)
Unit : V In case of 400V class inverter, setting is valid.
660-760
Description
Always run
Only during run However, inverter operates for
five minutes after power ON, and for five
minutes after inverter operation stops.
Chapter 4 Explanation of function
Description
t1
t2
ON
ON
100 second
(t1+t2+t3)
Usage ratio(%) =
100second
Relation code
b090:BRD use
b095:BRD action selection
b096:BRD on level
t3
ON
100
Relation code
b092:Cooling fan operation
selection