Free V/F Setting - Hyundai hiRUN N300 Series Instruction Manual

Vector inverter
Table of Contents

Advertisement

N300 INSTRUCTION MANUAL

(3) Free V/f setting

The free V/f setting optional V/f characteristics by setting the voltage and frequency in seven
parts.(b001-b113)
The setting of free V/f setting operates always to be 1 2 3 4 5 6 7.
Please set first free V/f setting 7 because the initial value is all 0Hz.
When the free V/f setting valid, the function of torque boost (A041/A241), basic frequency (A003/A203/A303),
maximum frequency(A004/A204/A304) is invalid. (Free V/f frequency 7 is treated as maximum frequency).
Set item
Free V/f frequency 7
Free V/f frequency 6
Free V/f frequency 5
Free V/f frequency 4
Free V/f frequency 3
Free V/f frequency 2
Free V/f frequency 1
Free V/f voltage 7
Free V/f voltage 6
Free V/f voltage 5
Free V/f voltage 4
Free V/f voltage 3
Free V/f voltage 2
Free V/f voltage 1
(Example)
(Note1) Even if you set 800V for free V/f voltage 1-7, output of inverter can't be more than input voltage or the
AVR setting voltage.
Function code
b112
b110
b108
b106
b104
b102
b100
b113
b111
b109
b107
b105
b103
b101
Output voltage(V)
V7
V6
V5
V4
V1
V2,V3
0
f1
Output voltage(V)
V7
V6
0
Chapter 4 Explanation of function
Date
0.-400.
0.-Free V/f frequency 7
0.-Free V/f frequency 6
0.-Free V/f frequency 5
0.-Free V/f frequency 4
0.-Free V/f frequency 3
0.-Free V/f frequency 2
0.0-800.0
f2
f3
f4 f5 f6 f7
f6
f7
Contents
Unit : Hz
Unit : V
(Note 1)
Output frequency(Hz)
Voltage to output or AVR
voltage
Output frequency(Hz)

Hide quick links: