Torque boost

A correctly installed motor and careful attention to voltage
drop in the wiring will improve the motor torque at low speed.
Setting of A041/A241 will select between manual torque
boost and automatic torque boost, the level of torque boost
corresponds to the set motor capacity selection (H003/H203)
and the motor pole selection (H004/H204).
Set item
Torque boost

Manual torque boost

Manual torque boost
break point
(1) Manual torque boost
The values set up with A042/A242/A342 and A043/A243/A343 is outputted.
A042/A242/A342 sets a percentage level where the base frequency voltage is 100%.
The level set is the value of torque boost output voltage at 0Hz.
When using the manual torque boost, it should be noted that overuse will cause saturation of the motor and
may cause damage.
The manual torque boost break point is the frequency at which the voltage torgue boost is switched off and
normal operation resumes.
To change of A041,A042,A043/A241,A242,A243/A342,A343 an intelligent input needs to be set to 08(SET)/
17(SET3) and switched on.
Output voltage(%)
A042/A242/A342

(2) Automatic torque boost

The output voltage is adjusted automatically by condition of the load.
When using automatic torque boost it important that the following two parameters art correctly.
In case of adding over-current protection at deceleration time, set AVR selection ON all the time.
Set item
Motor capacity selection
Motor pole selection
Chapter 4 Explanation of function
Function code
Date
00
A041/A241
01
A042/A242/
0.0-20.0
A342
A043/A243/
0.5-50.0
A343
100
A043/A243/A343
Base frequency
Function code
H003/H203
H004/H204
A041/ A241 :1 / 2 /3 torqrue boost selection
A042/A242/A342:1 / 2 /3 manual operation torque
A043/A243/A343:1 / 2 /3 manual operation torque
H003/H203 : 1 / 2 motor capacity selection
H004/H204 : 1 / 2 motor pole selection
Contents
Manual torque boost
Automatic torque boost
Unit : %
Level corresponding output
Voltage(100%)
Unit : %
Level corresponding to base frequency
Output frequency
(100%)
Setting limit
0.20-75.0(0.4 to 55kW)
0.20-160.0(75 to 150kW)
2/4/6/8
Relation code
st
nd
rd
st
nd
rd
boost
st
nd
rd
boost break point
st
nd
st
nd
Contents
Unit : kW
Unit : pole

Hide quick links:

Advertisement

Table of Contents
loading