4.3.2 Function mode

Output frequency setting

Setting the output frequency of the motor.
The output frequency is set by F001, when frequency command
select (A001) is set to 02.
Please frequency command select (A001) about other
methods of frequency setting.
When a frequency is set in F001, the same value is automatically set in 1 multi-stage zero speed
(A020) . Set up with F001 in the condition where turned on the set terminal, whether or not it sets up
with the 2nd multi-stage zero speed (A220) / the 3rd multi-stage zero speed (A320), in the case that
the 2nd/3rd control is set up.
In the case of using SET/SET3, you will need to assign 08 (SET) / 17(SET3) to an intelligent input
terminal.
Set item
Output frequency
setting
Multistage speed
A020/A220/A320
zero

Operation direction

This is effective when the operating command is set by the digital operator.
Function code
F004

Selection with limits of operation direction

The direction of the motor can be restricted.
Function code
b035
Frequency command selection
Select the method of frequency command.
When 0-10Vdc is inputted to the frequency command by 02-L
terminal, operation direction of motor reverses.
On output frequency monitor d001, you can't get information about forward/reverse. So be sure with
operation direction monitor d002.
Function code
A001
(Note 1) : Setting is possible at the time of the OPE-SR installation
Function code
F001
0.0, start frequency
st
1 /2 /3 maximum
frequency
Data
Contents
00
Forward
01
Reverse
Data
Contents
00
Forward/reverse is effective.
01
Only forward
02
Only reverse
Data
Contents
(Setting frequency with the potentiometer the digital operator has.) (Note1)
00
Setting frequency with control terminals (Terminals: O-L, O1-L, O2-L)
01
Setting frequency with digital operator (F001), remote operator
02
Setting frequency with RS485 terminals for communication
03
Setting frequency with option board 1.
04
Setting frequency with option board 2.
05
Chapter 4 Explanation of function
Data
Unit : Hz
"F001" = "A020"
nd
rd
Second control setting of "F001" = "A220"
Third control setting of "F001" = "A320"
Relation code
F001 : Output frequency setting
A001 : Frequency command
select
ST
A020/A220/A320 : 1 /2 /3
multistage speed zero
C001 - C008 : Intelligent input
terminal
st
Contents
Relation code
F004 : Operation direction
select
Relation code
d035 : Selection with limits of
operation direction
Relation code
A001 : Frequency command
Selection
nd
rd