Function Mode List When The Remote Operator Is Used - Hyundai J300 series Instruction Manual

J3005 vector inverter
Table of Contents

Advertisement

J300
INSTRUCTION MANUAL
5
12.3 Function mode

Function mode list when the remote operator is used

Function mode initial values and display contents
Initial display contents, initialization, and change ranges are displayed in the table indicated below.
(Function mode 1)
Display
Function
Function
sequence
No.
name
Base
frequency
1
F-00
setting
Maximum
frequency
2
F-01
setting
Start
frequency
3
F-02
adjustment
Motor input
voltage
setting
F-03
4
Input
voltage
AVR
function for
deceleration
Control
method
5
F-04
setting
Autotuning
setting
F-05
Motor
constant
6
(NOTE1)
Motor data
selection
Motor
capacity
setting
Motor pole
count
setting
Motor
constant R1
setting
Motor
constant R2
setting
Motor
constant L
setting
NOTE 1 : The motor constants R1, R2, L, M, J, Kp, Ti, and KPP vary with the capacity.
(Function mode 2)
Initialization display contents
F-BASE
60Hz
F-MAX
60Hz
Fmin
0.50Hz
AVR AC
440 V
AVR DEC
OFF
CONTROL
VC
AUX AUTO
NOR
AUX DATA
NOR
AUX K
005.50 kw
AUX P
AUX R1
1.004
AUX R2
0.776
AUX L
13.16 mH
Setting, change
Initialization
contents
30 to 120 (400)
60Hz
30 to 120 (400)
60Hz
0.5Hz
0.1 to 9.9
380, 400, 415,
440
440, 460
OFF
ON/OFF
VC, Vp1, VP2,
VC
Vp3, SLV , V2
NOR
NOR/AUT/NRT
NOR:Old Hitachi
general purpose
TOM:New Hitachi
NOR
general purpose
AUT:Auto-
tuning data
Rated
capacity of
0.75 to 220
each inverter
4p
4p
2, 4, 6, 8
Rated
0 to 65.535
capacity of
each inverter
Rated
capacity of
0 to 65.535
each inverter
Rated
Rated
capacity of
capacity of
0 to 655.35
each inverter
each inverter
Setting contents
When 120Hz is switched to 400Hz
by F-30, a frequency more than
120Hz can be set.
The equipment starts running
at this set value.
The motor input voltage is set.
ON or OFF of the A VR function
for deceleration is set.
When dynamic braking torque
is necessary fir deceleration OFF
is set.
VC, Vp1, Vp2, Vp3 : V/F
characteristics SLV : Sensorless
vector control V2: Sensor vector
control
At the first running after AUT/NRT
is set, the autotuning measurement
operations executed
The autotuning motor data before
starting autotuning measurement is
data equivalent to NOR
Set capacity smaller than the rated
capacity as capacity data.
The number of poles of the motor
to be used is set.