Removing The Housing; Adf Unit (Artisan 800/Px800Fw/Tx800Fw Only) - Epson Artison 800 Service Manual

Color inkjet printer
Table of Contents

Advertisement

Epson Artisan 800/Epson Stylus Photo PX800FW/TX800FW/Epson Artisan 700/Epson Stylus Photo PX700W/TX700W

4.2.2 Removing the Housing

4.2.2.1 ADF Unit (Artisan 800/PX800FW/TX800FW only)

Parts/Components need to be removed in advance:
None
Removal procedure
1.
Open the Scanner Unit.
The harness cover clamp needs to be cut when removing, and
C H E C K
cannot be reused. When installing the Cable Cover, replace it with a
P O I N T
new one.
Harness cover clamp before cut
Figure 4-2. Damaged stopper
2.
Cut the harness cover clamp with a nipper as shown in
the harness cover clamp.
3.
Slide the Cable Cover to the rear of the printer by pushing the point A of the
Cable Cover to release the hooks (x4) and ribs (x2), and remove the Cable
Cover.
Right side
Harness cover clamp
Cutting position
Cross-
section
Figure 4-3. Removing the Cable Cover
DISASSEMBLY/ASSEMBLY
Harness cover clamp after cut
Fig. 4-3
and remove
Harness cover clamp
Cable Cover
Point A
Hook
Rib
Disassembly Procedures
http://www.manuals4you.com
4.
Disconnect the ADF Motor Cable and ADF Sensor Cable from the connectors
on the Main Board. (See
Fig.
4-4.)
5.
Pull out the terminal of the Grounding Wire from the fixing rib of the frame.
Grounding Wire
Terminal of Grounding
Wire and the fixing rib
Main Board
ADF Sensor Cable
Figure 4-4. Removing the ADF Unit (1)
Revision C
ADF Motor Cable
102
Confidential

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents