Message
Source
Type
~
ACFT CONFIGURATION
AFT EQUIP HOT
APU FIRE
BAGGAGE DOOR
CABIN PRESSURE LOW
CABIN DFRN - 9.8
CHECK PFD
DAU 1-2 MISCMP-MSG
ENG FIRE LOOP ALRT
FLAME DETECT
GND SPOILER
L-R ENGINE HOT
L-R FUEL FILTER
L-R FUEL PRESS LOW
L-R PYLON HOT
L-R REV UNLOCK
L-ROIL PRES LOW
MAIN DOOR
SMOKE DETECT
FWC
DAU 1
DAU 1
DAU 2
DAU 1
DAU 1
FWC
FWC
DAU 1
DAU 2
DAU 2
DAU 1,2
DAU 1,2
DAU 1,2
DAU 1,2
DAU 1,2
DAU 1,2
DAU t
DAU 1
J1B-10
28/0
JIB-48
WSP 17, BIT7
28/0
JIB-47 WSP 17, BIT 6
28/0 ~
JIB-58
WSP 18, BIT 1
28/0
JIB-20 WSP 15, BIT 11
2;;: ~
JIB-70 WSP 18, BIT 12
CALCULATED
CALCULATED
JIB-69 WSP 18, BIT 11
G;O
JIB-31 WSP 16, BIT6
28/0
JIB-55 WSP 17, BIT 14
28/0
JIB-13
WSP 15, BIT4
28/0 ~
JIB-24
WSP 15, BIT 15
28/0
J1B-10
WSP 15, BIT 1
28/0
JIB-12
WSP 15, BIT3
28/0
JIB-9
WSP 15, BITO
28/0 ~
JIB-14
WSP
15, BIT5
28/0
JIB-20 WSP 15, BIT 11
28/0
JIB-31 WSP 16, BIT6
28/0
A9 1
Messa
e enable
state/normal
operation.
A
2
Message enable activates checklist auto callup. Engine fire
discrete (DAU 1,2 JIB-66, WSP 18, BIT 8) also activates.
CAS Red Warning Messages
Table 202
22-14-00
Page
281
Aug 15/91
Use or disclosure
of Information
on this page is subject to the restrlcttons
on the title page of th!s document.