CHAPTER 7 SPECIFICATIONS

Power

AC Power Requirements
DESCRIPTION
AC Input Voltage
AC Input Current
AC Power Consumption / Thermal Output (Maximum)
DESCRIPTION
1-PIM/MC
2-PIM/MC
3-PIM/MC
4-PIM/MC
5-PIM/MC
6-PIM/MC
7-PIM/MC
8-PIM/MC
Battery Requirements
DESCRIPTION
Max. Battery Capacity
DC Input Voltage for Battery
Built-in Battery Requirements
Physical Size of Built-in Battery
(one 12V battery)
Operating Environment
DESCRIPTION
Ambient Temperature
Relative Humidity
Electrical Characteristics (Central Office Trunk)
DESCRIPTION
Insulation Resistance
DC Resistance
Impedance
Leak Current
UNIVERGE NEAX 2000 IPS General Description
Issue 5
90 to 132Vac or 180 to 264Vac; 47 to 64Hz
3.5A(at 100V), 2.0A(at 200V)
AC Power Consumption (KVA)
100V
0.35
0.70
1.05
1.40
1.75
2.10
2.45
2.80
260AH per 4 PIM (65AH (12V) x 8)
-24V
3.4AH (12V) x 2 (approx. 30min. backup)
133(W) x 60(H) x 67(D) mm
0 to 40
Max. 90% (non-condensing)
15 mega-ohms or more at 100Vdc
On-hook conditions: 30 mega-ohms
Off-hook conditions: 1,700 ohms
On-hook conditions: 20 kilo-ohms (300 to 3,400Hz)
Looped conditions: 600 ohms
0 mA at on-hook conditions
SPECIFICATIONS
Thermal Output (BTU)
200V
100V
0.40
1,195
0.80
2,389
1.20
3,584
1.60
4,778
2.00
5,973
2.40
7,167
2.80
8,362
3.20
9,556
SPECIFICATIONS
SPECIFICATIONS
SPECIFICATIONS
8 kilo-ohms (at 24Hz)
200V
1,365
2,730
4,096
5,461
6,826
8,191
9,556
10,922