CARE AND MAINTENANCE

Your heater needs very little maintenance, but the following information will help you to keep it looking
good and working efficiently.
DO NOT attempt to clean the heater while the appliance is hot or operating.
All parts of the heater can be cleaned using a soft, damp cloth.
IMPORTANT
DO NOT use solvents or abrasives to clean any parts.
DO NOT spray aerosols in the vicinity of the heater whilst in operation.
DO NOT place articles on or against this heater.
DO NOT store flammable materials near this heater.

GENERAL OPERATION CHARACTERISTICS

NOTE: Before asking for a service call please check the following table as these characteristics are
part of the normal operation of the appliance and do not indicate a fault.
CHARACTERISTIC
At ignition:
Warm air does not start when the burner
lights.
Smoke or strange smells are produced on
the first start up after installation.
Sharp clicking noises at ignition, or when the
unit thermostat modulates to a lower or
higher setting, or shuts down.
During combustion:
Dull clunking noise when the thermostat
operates
When the appliance is turned off:
Convection fan continues to run after turning
'OFF'.

SERVICE

Rinnai recommend that this appliance and installation be inspected and serviced every 2 years or
more frequently.
If the power supply cord or any other component of the heater are damaged, they must be replaced
by Rinnai or a suitably qualified person.
Any service or repair work should only be carried out by an authorised person. Rinnai has service and
spare parts departments nationally. See back cover for contact details.
Service calls for general cleaning, maintenance and wear and tear are not necessarily
covered under the warranty. Service calls of this nature may be chargeable.
NOTE
Faults caused by insufficient gas supply, gas quality, installation errors or operation
errors are not covered by the Rinnai warranty. Refer to separate Warranty Card for
details.
Rinnai Australia
EXPLANATION
The room fan air is started automatically after a
short delay. This is to allow the heat exchanger to
warm up, helping to avoid cold draughts.
This is caused by grease, oil or dust on the heat
exchanger. This will stop after a short time.
This is simply expansion and contraction noise
from the heat exchanger.
This is the sound of the solenoid gas valves
opening and closing to regulate the gas flow.
This is to remove residual heat from the heat
exchanger and stops once the appliance cools.
15