Customer Information - Operation; Modes Of Operation; To Turn Remote 'On' Or 'Off; Manual Temperature Mode - Rinnai RDV3610ETR Operation Manual

Gas log flame fire
Table of Contents

Advertisement

CUSTOMER INFORMATION - OPERATION

MODES OF OPERATION

TO TURN REMOTE 'ON' or 'OFF'

To turn 'ON' - press and release the 'OK' and 'PWR' Buttons at the same time, display will now
include the setting temperature and the mode of operation.
To turn 'OFF' - press the 'PWR' Button only.

MANUAL TEMPERATURE MODE

Temperature can be set at any level.
Time and day of week does not need to be programmed to operate.
With the controller turned 'ON', press and release the 'A/M' button until the word 'MANUAL'
appears on the LCD. Press and hold the 'UP' or 'DOWN' buttons to increase/decrease the
temperature in increments of 1°C.

AUTOMATIC TIMER MODE

Temperature is regulated to the programmed level and time.
Time and day of week must to be set.
At any time the temperature may be manually adjusted 'UP' or 'DOWN'

FLAME MODE

Temperature control is over ridden and the flame size can be set to any setting from F7 highest to
F1 lowest. Note: When the fire first ignites it remains on highest flame for the first 45 seconds
before changing to the selected flame height.
Time and day of week does not need to be programmed.

MANUALLY OVERRIDING THE SET PROGRAM

At any time, the temperature or fan speed may be adjusted 'up' or 'down' similarly to operating in
'Manual' mode. However, whenever the thermostat changes to a new time period, the temperature
will be set automatically according to that period's setting.

PROGRAM MODES

The appliance can be programmed to operate during four separate periods in one day, resulting in a
possible 28 operating periods per week. A weekday program can be set so the program is used
Monday to Friday. Similarly, a weekend program can be set for Saturday to Sunday. The entire week
can also have the same program.
Factory default settings
To revert back to the default settings once you have reset the periods,
press the following sequence of buttons 'P' - 'T' - 'T' - 'DOWN'.

FLAME HEIGHT AND FAN SPEED

The flame height and fan speed are not individually adjustable. The flame height and fan speeds are
selected by the microprocessor according to the difference between the set temperature and the
ambient temperature of the room.
The flame can be between low and high depending if the set temperature has been reached, the
microprocessor will select the correct fan speed and flame height appropriate to the temperature
selected, i.e.; if the room is cold and a higher temperature is selected the unit will respond with a large
flame and high fan speed. As the air temperature in the room reaches the set temperature the flame
and fan speed will reduce in unison accordingly.
Rinnai Australia
If you do nothing to change the programming the following default
settings would be available if you set it to automatic mode.
Time Period
Start Time
Period 1
6:00 am
Period 2
8:30 am
Period 3
5:00 pm
Period 4
10.30 pm
11
.
Temperature
Suggested Time Period
°C
Settings
20°C
- Morning
15°C
- Day time
21°C
- Evening
15°C
- Night time
Operation & Installation Manual

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rdv3611etrSymmetry rdv 3610

Table of Contents