N300-P INSTRUCTION MANUAL
Second/Third control function (SET, SET3)
This control function is used when the Inverter is connected to two different types of motors. By assigning
08 (SET).17(SET3) to an intelligent input terminal and turning SET/SET3 terminal ON/OFF you can switech
between three different inverter set-ups.
nd
rd
select 2 /3 control function while the Inverter is in the STOP condition.
The functions which can change with SET terminal
st
F002/F202/F302 : 1 /2 /3 acceleration time
st
F003/F203/F303 :
1 /2 /3 deceleration time
st
A003/A203/A303 : 1 /2 /3 base frequency
st
A004/A204/A304 : 1 /2 /3 max. frequency
st
A020/A220/A320 : 1 /2 /3 multi-speed 0 setting
st
nd
A041/A241 : 1 /2 torque boost selection
st
A042/A242/S342 : 1 /2 /3 manual torque boost
st
A043/A243/A343 : 1 /2 /3 manual torque boost point
st
A044/A244/A344 : 1 /2 /3 control system
st
A061/A261/A361 : 1 /2 /3 frequency upper limiter
st
A062/A262/A362 : 1 /2 /3 frequency lower limiter
st
A092/A292/A392 : 1 /2 /3 acceleration time 2
st
A093/A293/A393 : 1 /2 /3 deceleration time 2
st
nd
A094/A294 : 1 /2 two-stage adjustable speed selection
st
nd
A095/A295 : 1 /2 two-stage acceleration frequency
st
nd
A096/A296 : 1 /2 two-stage deceleration frequency
st
b012/b212/b312 : 1 /2 /3 electronic thermal level
st
b013/b213/b313 : 1 /2 /3 electronic thermal characteristic selection
st
nd
H002/H202 : 1 /2 motor constant selection
st
nd
H003/H203 : 1 /2 motor capacity selection
st
nd
H004/H204 : 1 /2 motor pole selection
st
nd
H005/H205 : 1 /2 speed answer
H006/H206/H306 : 1 /2 /3 stabilized constant
st
nd
H020/H220 : 1 /2 Motor R1
st
nd
H021/H221 : 1 /2 Motor R2
st
nd
H022/H222 : 1 /2 Motor L
st
nd
H023/H223 : 1 /2 Motor I
st
nd
H024/H224 : 1 /2 Motor J
st
nd
H030/H230 : 1 /2 Motor R1 (Auto-tuning)
st
nd
H031/H231 : 1 /2 Motor R1 (Auto-tuning)
st
nd
H032/H232 : 1 /2 Motor L (Auto-tuning)
st
nd
H033/H233 : 1 /2 Motor I
st
nd
H034/H234 : 1 /2 Motor J (Auto-tuning)
st
nd
H050/H250 : 1 /2 PI proportion gain
st
nd
H051/H251 : 1 /2 P proportion gain
Display during setting isn't differentiated between the 1 control function or the 2 /3 control function function.
So confirm it in the state of ON/OFF of termnal. Even 1 /2 /3 control is changed during run, it will not be
active until the inverter is stopped. When both of the SET and SET 3 terminals are turned on it becomes the
nd
2 control function.
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
nd
rd
st
nd
rd
0
(Auto-tuning)
0
Chapter 4 Explanation of function
Inverter
SET
CM1
st
st
nd
rd
U
V
W
nd
rd
Motor1
Motor2