Input terminal a/b(NO/NC)selection
It is possible to set a contact input or b contact input to
intelligent input terminals 1-8 and FW terminals individually.
Set item
Intelligent input 1-8
a/b(ON/NC) selection
Input FW
a/b(ON/NC) selection
Multi-speed operation function
It is possible to set multiple operation speeds and switch
between the speed with the terminals.
Multi-speed operation can be selected by binary operation
(max.16speeds)with 4 terminals or by bit operation
(max.8 speeds) with 7 terminals.
Set item
Multi-speed
selection
A020/A220/A320
Multi-speed 0-15
(1) Binary operation
It is possible to set multi-speed 0 to 15 by selecting 02 to 05( CF1 to CF4) on the intelligent input terminals.
Set frequency setting for speed 1 to 15 with A021-A035.
Set 0 speed with A020/A220/A320 or F001 when frequency command is operator.
Or when frequency command is control terminal (Terminal), set with O, O1, O2 terminal.
Multi-speed
CF3
CF4
0 speed
OFF
OFF
1 speed
OFF
OFF
2 speed
OFF
OFF
3 speed
OFF
OFF
4 speed
OFF
5 speed
OFF
6 speed
OFF
7 speed
OFF
8 speed
OFF
ON
9 speed
OFF
ON
10 speed
OFF
ON
11 speed
OFF
ON
12 speed
ON
13 speed
ON
14 speed
ON
15 speed
ON
Function
Data
Descripition
code
a contact (ON)
00
C011-C018
b contact (NC)
01
a contact (ON)
00
C019
b contact (NC)
01
Function code
A019
0.00, start frequency-max.
-A035
CF2
CF1
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
OFF
OFF
OFF
ON
ON
OFF
ON
ON
ON
OFF
OFF
ON
OFF
ON
ON
ON
OFF
ON
ON
ON
Chapter 4 Explanation of function
a contact : ON with Close, O FF with open
b contact : ON withOpen, O FF with close
RS terminal can set only a contact
A019 : Multi-speed selection
A020/A220/A320 : 1st/2nd/3rd multi-
A021 A035 : Multi-speed 1-15
C001 C008 : Intelligent input terminal
Set value
Change to binary operation 16 speed
00
Change to bit operation 8 speed
01
Units : Hz
frequency
11speed
10speed
9speed
4speed
5speed
3speed
6speed
2speed
7speed
1speed
CF1
CF2
CF3
CF4
FW
Relation code
C011 C018 : Intelligent input
a/b(NO/NC) selection
C019 : Input FW a/b (NO
/NC)Selection
Relation code
stage speed zero speed
Description
Frequency command
12speed
form operator or analog
13speed
external input terminal.
14speed
15speed
0speed
8speed