Hyundai N300-P Instruction Manual page 30

Economical inverter
Table of Contents

Advertisement

N300-P INSTRUCTION MANUAL
(1) Explanation of main circuit terminals
Symbol
Terminal Name
R,S,T
Main power
(L1,L2,L3)
U, V, W
Inverter output
(T1,T2,T3)
PD,P
D.C reactor
(+1,+)
P,RB
External braking resistor
(+,RB)
P,N
External Regenerative unit
(+,-)
G
Inverter earth terminals
(2) Explanation of control circuit terminal
Terminal Name
Symbol
Analogue power
Power
L
common
Source
H
Frequency power
Frequency
O
command power
Frequency
terminal(voltage)
setting
Frequency command
O2
support(voltage)
Frequency command
OI
Terminal (current)
Digital monitor
AM
Analogue monitor
AMI
(Current)
Monitor
Digital monitor
FM
(Voltage)
Interface power
P24
Power
Source
Interface power
CM1
common
Intelligent input
PLC
FW
Forward command
1(RS)
2(AT)
Input intelligent
3(JG)
4(FRS)
5(2CH)
6(CF2)
7(CF1)
8(RV)
11(FA1)
12(RUN)
13(OL)
input Intelligent
14(OTQ)
15(IP)
AL0
Common terminal
AL1
Alarm output
AL2
terminal
Thermistor input
TH
terminal
Connect alternating power supply.
Connect three- phase motor.
Remove the short bar between PD and P, connect optional power factor reactor(DCL)
Connect optional External braking resistor. ( Installed on 5.5kW to 15kW )
Connect optional Regenerative braking unit (BRD).
It is earth terminals of inverter case.
It is common terminal of frequency command signal(O, O2, OI)
and analogue output, AM, AMI. Don"t earth.
It is the DC+10V power for terminals.
When inputting DC 0 ~10V, it is maximum frequency on 10V.
When maximum frequency is expected to be on being less then 10V,
set with A014
When inputting DC 0 ~ 10V, this signal is added to frequency
command of O or OI terminal.
When inputting DC 4 ~20mA, 20mA is maximum frequency.
When only terminal is ON, this input signals is effective.
(voltage)
Output one selected from monitor item, output frequency, output
current, torque, output voltage, input electric power, electric thermal
rate, LAD frequency
Output the output frequency with digital besides above monitor.
It is DC24V power for connection input signal. When selecting source
logic, it's connection input common
The common terminal is FW terminal, 1-8 terminal, TH terminal,
FM terminal, Don't earth.
Change sink type and source type by short bar on control terminals.
P24-PLC : Sink type CM1-PLC : Source type
common
About FW signal, ON is Forward and OFF is stop command.
Select 8 function from 44 functions, and divide between 1 terminal
and 8 terminals.
Select 5 function from 22 functions, and divide between 1 terminal
and 5 terminals.
It is common terminal of alarm output terminal
Assign output function. Output is c contact
When a Thermistor connected to terminals TH and CM1, the inverter
checks for over-temperature and will cause trip event and turn off
output to motor.
Chapter 2 Installation and Wiring
Explanation o f contents
Explanation o f contents
Allowable load current 20mA
Input Impedance 10K ohm
Allowable maximum voltage 12V
Input Impedance 10K ohm
Allowable maximum load
current 20mA
Input Impedance 100 ohm
Allowable maximum current 24mA
Allowable maximum current 2mA
Allowable output less then
impedance 250 ohm
Allowable maximum current1.2mA
Maximum frequency 3.6kHz
Allowable maximum output
current 100mA
Allowable maximum
voltage 27V
Input ON condition of terminal
voltage
Over 18V
Input OFF condition of terminal
voltage
under 3 V
Input impedance 4.7k ohm
Allowable maximum
voltage 27V
current 50mA
Allowable minimum
AC250V, 0.2A
Allowable minimum
AC100V,10mA
Allowable minimum
Thermistor power 100mW