N300-P INSTRUCTION MANUAL
(3) Device Net option board(N-DN)
The table below is the setting method of Baud rate (Front view of the option board)
( , indicate direction for switch of Dip switch)
Dip switch
Setting
(Note) Do not switch on DR1 and DR0 at the same time.
The table below is the setting method of MAC ID (Front view of the option board)
MAC ID.
MAC ID.
1
0
(OFF)
NA32 NA16
NA8
NA4
125kbps
DR
ON
OFF
DR1 DR0
Figure left describes the direction of Dip switches. See below.
Bottom : 0 Upper : 1
Bit increases from right to left switches.
Therefore, figure left becomes formula below.
5
4
1 2 +0 2 +1 2 +0 2 +0 2 +1 2 = 29(Hex) = 41(dec)
NA2
NA1
NA32 NA16
NA8
Chapter 4 Explanation of function
250kbps
DR
ON
OFF
DR1 DR0
Dip switch setting
3
2
1
0
NA4
NA2
NA1
500kbps
DR
ON
OFF
DR1 DR0