Approval & Codes
This appliance is certifi ed to ANSI Z21.88-2014/
CSA 2.33-2014 American National Standard / CSA
Standard for Vented Gas Fireplace Heaters for use in
Canada and USA, and to CGA 2.17-91 High Altitude
Standard in Canada. This appliance is for direct vent
installations.
This appliance complies with CSA P4.1-09 Testing
method for measuring annual fi replace effi ciencies.
The installation must conform to local codes or, in
the absence of local codes, with the National Fuel
Gas Code, ANSI Z223.1 or the Natural Gas and
Propane Installation Code CAN/CGA-B149. Only
qualifi ed licensed or trained personnel should
install this appliance.
This appliance must be electrically grounded in
accordance with local codes, or, in the absence of
local codes, with the National Electrical Code, ANSI/
NFPA 70 or the Canadian Electrical Code, CSA C22.1.
Ratings
Model
Gas
Altitude (Ft.)*
Input Maximum (Btu/h)
Input Minimum (Btu/h)
Manifold Pressure (in w.c.)
Minimum Supply Pressure
(in w.c.)
Maximum Supply Pressure
(in w.c.)
Main Burner Injector
Marking
Pilot Injector Marking
Min. Rate By-Pass Screw
*High Altitude Installations
I nput ratings are shown in BTU per hour and are
certifi ed without deration for elevations up to 4,500
feet (1,370 m) above sea level.
For elevations above 4,500 feet (1,370 m) in USA,
installations must be in accordance with the current
ANSI Z223.1 and/or local codes having jurisdiction.
Heating value of gas in some areas is reduced to
compensate for elevation—consult your local gas
utility to confi rm.
Specifi cations
N
P
Natural
Propane
0-4,500 feet*
36,000
31,000
15,000
15,000
3.6"
10.5"
5"
11"
10"
14"
Cat #
Cat #
82-1200
92-360
#51
#30
#190
#125
For installations at elevations above 4,500 feet
(1,370 m) in Canada, please consult provincial
and/or local authorities having jurisdiction.
Supply Gas
Heater engine 1200EAN is used with natural gas.
Heater engine 1200EAP is used with propane gas.
The supply pressure must be between the limits
shown in the Ratings section above.
X
The supply connection is 3/8 inch NPT male and
located on the left hand side of the fi rebox. A shut-off
valve (not supplied) is required on the supply line to
isolate the unit during service.
Conversion Kits
The 1200 Ventana is supplied as natural gas or
propane gas and is fi eld convertible between fuels.
See instructions packaged with the conversion kit
for further information.
Electrical
The 1200 does not require an electrical power source
to operate as a heater. However, it requires electrical
power to operate its decorative hearth light.