Valor Ventana 1200EAN Installation & Owner's Manual page 30

Direct vent zc fireplace
Table of Contents

Advertisement

QUALIFIED
INSTALLER
How to Read the Venting Chart
The chart below applies to roof or wall termination.
1. The total length of the vent pipe cannot exceed
40 feet (12.2 m).
2. The minimum vertical height with roof termination
is 6 feet (1.83 m).
3. Any combination of rise and run can be used as
long as they are within the allowable limits shown
on the chart below.
4. A maximum of 4 x 90 degrees elbows—or
equivalent (2 x 45 degr. = 90 degr.)—can be used.
Venting Chart
Venting Chart
4 x 90º ELBOWS
4 x 90º ELBOWS
MAXIMUM (or equivalent)
MAXIMUM (or equivalent)
V2
H1
MINIMUM
VERTICAL
RISE: 2'
Min. 2'
before
elbow
V1
Example 1
V Value = V1 (6') + V2 (6') + V3 (2')= 14'
H Value = H1 (3') + H2 (3') = 6'
#2 Restrictor position required
30
Co-axial Venting
Top of
horizontal
H2
pipe
3"
1"
Bottom & sides
of horizontal pipe
All around
1"
vertical
pipe
Max. 24" pipe if
Min. 12"
min. vertical rise
pipe
is used
Max. 6" pipe
if min. vertical
rise is used
45º elbow
directly on
fl ue collar
No Restrictor
5. Each 90 degrees elbow installed on the horizontal
plane is equivalent to a 3 feet horizontal pipe;
therefore, 3 feet must be subtracted from allowable
horizontal run (45 degrees elbow is equivalent to
18 inches horizontal pipe.)
6. All horizontal pipe runs must be graded 1/4 inch per
foot upwards in the direction of the exhaust fl ow.
The fi nal pipe length, when terminating through the
wall may be graded downwards slightly to prevent
water migration.
7. A restrictor is required for many installations—see
next section.
V3
Allowable Vent
Confi gurations
40
40
38
38
36
36
34
34
#4
#4 Restrictor
32
32
30
30
28
28
26
26
#3 Restrictor
24
24
22
22
20
20
18
18
Example 1
16
16
14
14
12
12
10
10
8
8
6
6
4
4
2
2
4
HORIZONTAL RUN (ft)
NO INSTALLATION
#2 Restrictor
#1 Restrictor
NO INSTALLATION
6
8
10
12
14
16
18
20

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Ventana 1200eap

Table of Contents