STELVIO 1200 NTX
Devices activation screen page
DEVICES ACTIVATION
This screen page is used to delete errors in the
control unit memory and to activate some systems
controlled by the control unit.
Specification
Left coil
Right coil
Left injector
Right injector
Error clearing
Fuel pump
Stepper control
Errors display screen page

ERRORS DISPLAY

This screen page shows potential errors detected
in the vehicle (ATT) or stored in the control unit
(MEM) and it allows to check error clearing (STO).
Specification
Pressure sensor
Air temperature
Engine temperature
Throttle actuator position sensor
Lambda probe
Left injector
Revente Interdite - Revendita Vietata - Resaling Forbiden - Wiederverkauf Verboten
DEVICES ACTIVATION
By pressing the 'enter' button, the stored errors (MEM) become
part of the historical data (STO). In the next connection be-
tween the Axone and the control unit, the historical errors
For 4'', advancement control of 32 steps; for the next 4'', retro-
cession control of 32 steps and so on for 30''
ERRORS DISPLAY
Possible short circuit in the earth lead, battery or open circuit:
recovery function noticeable for customer. Careful with the air
pressure sensor in the instrument panel
Possible short circuit in the earth lead, battery or open circuit:
recovery function hardly noticeable for customer.
Possible short circuit in the earth lead, battery or open circuit:
Possible short circuit in the earth lead, battery or open circuit:
recovery function noticeable for customer.
Possible short circuit on the earth lead, battery or open circuit
or plausibility: recovery function hardly noticeable for customer.
Possible short circuit in the earth lead, battery or open circuit.
If both injectors do not work, the engine does not work
Desc./Quantity
operation for 2.5 m, 5 times
operation for 2.5 m, 5 times
Operation for 4 m, 5 times
Operation for 4 m, 5 times
(STO) are no longer shown
Operation for 30''
Desc./Quantity
recovery function.