Installing countertop dispensers without
legs
1. Position dispenser in desired location,
mark dispenser outline on counter and
remove dispenser.
2. Regardless of whether utilities will exit
through back or bottom of dispenser, drill
four (4) 7/16" holes in counter to anchor
dispenser to counter (Fig. 2).
3. For utilities exiting through bottom
only:
(a) Make cut out as shown in
Fig. 2.
(b) Move drain fitting from back of dispenser
and mount where shown in Fig. 3.
(c) Cut drain tube to length and attach to
barbed connection.
(d) Move inlet water fitting from back of
dispenser and mount where shown in
Fig. 3.
(e) Cut water tubing to length and re-insert
into water fitting.
Follett countertop dispensers can have any or all
utilities run directly through counter or out rear of
dispenser. For dispensers with any utilities exiting
through counter, make counter cut-out.
4. If ice transport tube will exit out rear of
dispenser, remove ice transport tube
knock-out (Fig. 4) from rear of dispenser.
Note: Utility connections can be accessed through
front of dispenser by removing stainless steel
splash panel, or by removing access panel (Fig. 1)
on back of dispenser.
25CR/HR/FB and 50CR/HR/FB
Fig. 2
21" (53.3 cm)
20.125" (51.1 cm)
1"
(25.4 mm)
cut-out
9" X 16"
.375" holes
(22.9 cm x 40.7 cm)
(9.52 mm)
drain pan
Fig. 3 – Bottom exiting utilities (countertop units)
.44" (11 mm)
10.5"
1.5" (38 mm)
(26.7 cm)
12.5"
(31.7 cm)
16.5"
(41.9 cm)
.375 (10 mm)
6.5"
(16.5 cm)
Bracket
Drain
Drain Tube
Fitting
Inlet
Fitting
7