Installation; Before You Begin; Installing Countertop Dispensers Without Legs - Follett 12CI425A-LI Operation And Service Manual

Symphony plus 12 series
Table of Contents

Advertisement

Installation

Before you begin

§ All dispensers must be installed level in both directions to ensure proper operation.
§ Service and ventilation clearances: 6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top for ventilation
and 12" (30.5 cm) at top recommended for service.
§ Countertop units installed without legs provide the option of taking utilities out bottom or back of dispenser
(on wall mount units and countertop units with legs, utilities exit from back). See counter cutout drawings for
bottom exiting utilities on units with and without drain pans. For installations where utilities exit through back
of dispenser, refer to back view drawings.
§ Wall mount models without drain pan are designed for use above sinks.
§ Counter depth must allow front of sink to be a minimum of 30.00" (76.2 cm) from wall.
Installing countertop dispensers without
legs
1. Position dispenser in desired location,
mark dispenser outline on counter and
remove dispenser.
2. Regardless of whether utilities will exit
through back or bottom of dispenser, drill
four (4) 7/16" holes in counter to anchor
dispenser to counter (Fig. 1).
3. For utilities exiting through bottom
only:
(a) Make cut out as shown in
Fig. 1.
(b) Move drain fitting from back of dispenser
and mount where shown in Fig. 2.
(c) Cut drain tube to length and attach to
barbed connection.
(d) Move inlet water fitting from back of
dispenser and mount where shown in
Fig. 2.
(e) Cut water tubing to length and re-insert
into water fitting.
4. For all units: Apply a thick bead
approximately 1/4" (6 mm) diameter of
NSF-listed silicone sealant (Dow Corning
RTV-732* or equivalent) 1/4" (6 mm)
inside marked outline of dispenser.
5. Carefully lower dispenser on counter in
proper position and secure to counter
with four (4) 3/8"-16UNC bolts.
6. Smooth excess sealant around outside of
dispenser.
* Dow Corning is a registered trademark of Dow Corning Corporation in the United States and other countries.
12CI425A • 12HI425A
Fig. 1
16.00"
(40.7 cm)
4X
14.37"
Ø.437"
(36.5 cm)
(11 mm)
1.50"
hole
(3.8 cm)
Cutout
connections
12.00"
through
(30.5 cm)
bottom
12.00"
(30.5 cm)
Fig. 2 - Bottom exiting utilities (countertop units)
0.81"
(2.1 cm)
1.04"
(2.6 cm)
2.00"
(5.1 cm)
17.87"
(45.4 cm)
16.00"
(40.7 cm)
5.62"
(14.3 cm)
bracket
drain
drain tube
tting
inlet
tting
5