Ventilation Clearances; Approximate Shipping Weight; Installation; Before You Begin - Follett Symphony Plus 25 series Operation And Service Manual

25 and 50 series ice and water dispensers
Hide thumbs Also See for Symphony Plus 25 series:
Table of Contents

Advertisement

Ventilation clearances

§ No clearance required for countertop dispensers and wall mount dispenser models with RIDE ice machine
(25CR425A/W, 50CR425A/W, 25HR425A/W, 50HR425A/W).
Note: 12" (30.5 cm) at top advised for service.
§ 4" (10.2 cm) required at rear for freestanding models (25FB425A/W, 50FB425A/W).
Note: 12" (30.5 cm) at top advised for service.

Approximate shipping weight

§ 25/50 CR/HR: 310 lb (141 kg)
§ 25/50 FB 230 lb (105 kg)

Installation

Before you begin

§ All dispensers must be installed level in both directions to ensure proper operation.
§ All countertop dispensers provide the option of taking utilities out the bottom or back of the dispenser.
See counter cut-out (Fig. 3) for bottom exiting utilities on units with and without drain pans. For installations
where utilities will exit through back of dispenser, refer to back view drawings.
§ Wall mount models are designed for use above sinks or custom drain pans, and are not normally equipped
with integral drain pans. Front of sink should be a minimum of 23" (58.4 cm) from back wall. Connection of
utilities through the back for wall mount units is the same as shown in drawings for countertop models except
that the drain pan is absent.
§ SensorSAFE dispensers are shipped with a plastic, protective film on sensor lenses. For proper operation,
plastic film must be removed after installation.

Installing freestanding dispensers

1. Position dispenser in desired location and adjust legs to level in both directions.
2. Connect water supply to 3/8" FPT fitting on back of dispenser (Fig. 1).
3. Connect separate drain lines to 3/4" MPT dispenser drain fitting, and 3/4" MPT ice machine drain
fitting on back of dispenser.
4. Run drain lines to wall or floor drain. If ice machine drain fitting is below an intended wall drain, a
condensate pump must be used.
5. If ice machine is a water-cooled unit, connect water-cooled condenser supply line to 3/8" FPT
condenser inlet fitting on back of dispenser.
Note: Do not run condenser supply water through ice machine water filter system.
6. Connect condenser drain line to 3/8" FPT condenser outlet fitting on back of dispenser.
Important: Do not connect condenser drain line to any other drain lines.
7. Plug dispenser into 15A rated NEMA 5-15 wall socket.
8. Remove front cover of base section by removing two screws at bottom corners of cover. Allow cover
to drop approximately 3/8" (5 mm) and pull forward.
9. Turn on water supply and check for leaks.
25CR/HR/FB and 50CR/HR/FB