Specifications

16.00"
(40.7 cm)
Front View

Electrical

§ 115 V, 60 Hz, 1 phase, 11.0A
§ Connect to a 15A dedicated circuit.

Ambient

Air temp*
Water temp
Water pressure (psi/bar)
* Ambient air temperature is measured at the air-cooled condenser coil inlet.
Ambient water temperature is measured in the ice machine reservoir.

Plumbing

Dispenser drain
Water inlet
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain at
least 1/4" per foot (20 mm per 1 m) run of slope.

Ventilation clearances

§ 6" (15.3 cm) on right side of dispenser, 6" (15.3 cm) at top, and 12" (30.5 cm) at top recommended for service.
Note: Do not block right side air intake or top air exhaust.

Dry weight

§ 144 lb (65 kg)
4
12CI425A, 12HI425A
22.625"
(57.5 cm)
4.00"
(10.2 cm)
23.5"
(59.7 cm)
Side View
100 F/38 C Max.
90 F/32 C Max.
70/5 Max.
32.00"
(82.6 cm)
18.00"
(45.8 cm)
50 F/10 C Min. Best performance below 80 F (27 C)
45 F/4 C Min. Best performance below 70 F (21 C)
10/0.7 Min.
12CI425A
3/4" MPT
3/8" FNPT
air exhaust
3/4" MPT drain
3/8" FPT
water inlet
air
intake
power cord (NEMA 5-15)
Rear View
12HI425A
3/4" MPT
3/8" FNPT