Specifications; Electrical; Ambient; Plumbing - Follett 25FB425A Operation And Service Manual

Ice and water dispensers
Table of Contents

Advertisement

Specifications

Electrical

§ Freestanding models (25FB425A/W, 50FB425A/W) require a dedicated circuit.
Basic electrical: 115 V/60 Hz/1 phase
§ Dispensers and RIDE ice machines are supplied with 7-foot power cord with NEMA 5-15 hospital-grade plug.
Connect to a dedicated 15A dedicated circuit.
Note: It is preferred that circuit be protected by a GFCI.
Model
25FB425A/W, 50FB425A/W

Ambient

Air temp
Water temp
Water pressure (psi/bar)

Plumbing

Dispenser drain
Ice machine drain
Dispenser water inlet
RIDE IM water inlet
Cond. inlet – w/c only
Cond. drain – w/c only
Note: Water shut-off recommended within 10 ft. (3 m) of dispenser. Drain to be hard-piped and insulated. Maintain
at least 1/4" per foot (20 mm per 1 m) run of slope.

Ventilation clearances

§ 4" (10.2 cm) required at rear for freestanding models (25FB425A/W, 50FB425A/W).
Note: 12" (30.5 cm) at top advised for service.
Dry weight
§ 25/50 FB 212 lb (96 kg)
4
25FB425A/W, 50FB425A/W
Total system
11.0A
Electrical connection
cord & plug provided
100 F/38 C Max.
50 F/10 C Min. (Best performance below 80 F/27 C)
90 F/32 C Max.
45 F/7.2 C Min. (Best performance below 70 F/21 C)
70/5 Max.
10/0.7 Min.
25/50 FB with ice machine in base
3/4" MPT
3/4" MPT
3/8" FPT
3/8" FPT
3/8" FPT
Max. fuse
15A
Circuits required
115/60/1, 20A max. fuse size

Advertisement

Table of Contents
loading

Table of Contents