Electrical

§ 115 V, 60 Hz, 1 phase, 11 .0A
§ Connect to a 15A dedicated circuit .
§ Furnished with 7 ft (2 m) power cord with a 90° NEMA hospital grade 5-15 plug .

Ambient

Air temp*
Water temp
Water pressure
* Ambient air temperature is measured at the air-cooled condenser coil inlet .
Ambient water temperature is measured in the ice machine float reservoir .

Plumbing

Dispenser drain
Water inlet
Condenser inlet
Condenser outlet
Note: Water shut-off recommended within 10 ft . (3m) of dispenser . Drain to be hard-piped and insulated . Maintain at
least 1/4" per foot (20mm per 1m) run of slope .

Ventilation clearances

Required for ventilation
Suggested for service
Note: Do not block right side air intake or right side air exhaust .

Uncrated weight

§ 25/50 CI425A/W (countertop): 215 lbs . (98 kg)
§ 25/50 HI425A/W (wall mount): 230 lbs . (105 kg)
25CI425A/W, 25HI425A, 50CI425A/W, 50HI425A
100 F/38 C Max .
50 F/10 C Min . (Best performance below 80 F (27 C)
90 F/32 C Max .
45 F/7 C Min . (Best performance below 70 F (21 C)
70 P .S .I ./5Bar Max .
10 P .S .I ./0 .7 Bar Min .
Connections 25/50CI425A
Water-cooled 3/8" FPT
Water-cooled 3/8" FPT
3" (77 mm) each side
12" (30 .5 cm) top,
6" (15 .3 cm ) left side
3/4" MPT
3/8" FPT
Air-cooled
Rough-ins 25/50HI425A
Air-cooled 3/4" FPT
3/8" FPT
N/A
N/A
Water-cooled
N/A
12" (30 .5 cm) top
5