Broil Element Does Not Heat - Electrolux NEXT GEN Service Manual

30” electric freestanding ranges
Hide thumbs Also See for NEXT GEN:
Table of Contents

Advertisement

element is defective. If the meter reads zero the
wiring to the element is open.
If the control appears to be operating normally but the

broil element does not heat:

1. Go to the back of the oven control and measure the
voltage drop between terminals BR and pin 4 of the
6 pin plug (neutral) with the control not programmed
(clock operating only). If the meter reads line to
neutral (120 VAC) the control is defective. If the
meter reads zero the broil element or the wiring to
the broil element is defective. Go to step 2.
2. Remove the back from the range to gain access to
the terminals of the broil element. Program the oven
control for broil and measure the voltage drop across
the terminals of the broil element. If the meter reads
line to line voltage (240 VAC) the element is
defective. If the meter reads zero the wiring to the
element is open.