Stop Bit; Flow Control - CipherLab Cipher Lab 1560 User Manual

Table of Contents

Advertisement

2.5.5 STOP BIT

2.5.6 FLOW CONTROL

By default, there is no flow control in use. Select the flow control (handshake) method.
Options
No
Scanner Ready
Data Ready
Inverted Data Ready
Description
No flow control
The scanner will activate the RTS signal upon powering on. After each good
read, the scanner will then wait for the CTS signal to become active. Data
will not be sent until the CTS signal becomes active.
The RTS signal will be activated after each good read. The scanner will then
wait for the CTS signal to become active. Data will not be sent until the CTS
signal becomes active.
It works the same as the Data Ready flow control except that the RTS signal
level is inverted.
Chapter 2
Selecting Output Interface
2 stop bits
*1 stop bit
*None
Scanner Ready
Data Ready
Invert Data
Ready
Update
85

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cipher lab 156215601562