Maintenance and Inspection
Monthly and
Yearly Inspection
Chart
General Ambient
Main
circuits
Cooling
system
Control
circuit
Display LEDs
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Item Inspected
Check for...
Extreme
environment
temperatures
& humidity
Major devices
Abnormal
vibration,
noise
Power supply
Voltage
voltage
tolerance
Ground
Adequate
Insulation
resistance
Mounting
No loose
screws
Components
Overheating
Housing
Dirt, dust
Terminal block
Secure
connections
Smoothing
Leaking,
capacitor
swelling
Relay(s)
Chattering
Resistors
Cracks or
discoloring
Cooling fan
Noise
Heat sink
Dust
General
No odor,
discoloring,
corrosion
Capacitor
No leaks or
deformation
Legibility
Inspection
Cycle
Inspection Method
Month
Year
✔
Thermometer,
hygrometer
✔
Visual and aural
✔
Digital volt meter,
measure between
inverter terminals
[L1], [L2], [L3]
✔
Megger test
✔
Torque wrench
✔
Thermal trip events
✔
Visual
✔
Visual
✔
Visual
✔
Aural
✔
Visual
✔
Power down,
manually rotate
✔
Visual
✔
Visual
✔
Visual
✔
Visual
6–17
SJ700
Inverter
2
Criteria
Ambient temperature
between -10 to 50°C,
non-condensing
Stable environment for
electronic controls
200V class:
200 to 240V 50/60 Hz
400V class:
380 to 460V 50/60 Hz
500VDC, reading of 5M
ohms or greater, see next
section for test details
M3: 0.5 – 0.6 Nm
M4: 0.98 – 1.3 Nm
M5: 1.5 – 2.0 Nm
No trip events
Vacuum dust and dirt
No abnormalities
No abnormalities
Single click when
switching ON or OFF
Use Ohm meter to check
braking resistors
Rotation must be smooth
Vacuum to clean
No abnormalities
Undistorted appearance
All LED segments work