Hitachi SJ7002 Series Instruction Manual page 122

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

Miscellaneous
Settings
Func.
Code
B034
Run/power-on warning time
B035
Rotational direction restriction
B036
Reduced voltage start selection
Function Display
Settings
Func.
Code
B037
Function code display
restriction
B038
Initial display selection
B039
Automatic user parame-
ter function enable
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
The miscellaneous settings include scaling factors, initialization modes, and others. This
section covers some of the most important settings you may need to configure.
Name/
Description
FREE
FW
RV
The inverter has the (optional) capability to suppress the display and editing of certain parame-
ters. Use B037 to select the display options. The purpose of this feature is to hide particular
secondary parameters that become unused or not applicable based on more fundamental param-
eter settings. For example, setting A001 = 01 configures the inverter to get its frequency
command from the front keypad potentiometer. In this case, the inverter will not use the analog
inputs nor their adjustment parameters for an external frequency command.
Keypad
Name/
Description
SRW
ALL
FUNCTION
USER
COMPARE
BASIC
STR
FM
Iout
Dir
F-CNV
F-SET
OFF
ON
For example, you can set B037=01 to have the inverter suppress the displaying of all analog
input parameters when A001=01, as shown in the first row of the following table.
Function
Code
A001
Keypad
Range and Settings
SRW
OPE
0 to 9999. (0 to 99990), 1000 to
6553 (10000 to 655300) (hours)
00
Enable for both directions
0 1
Enable for forward only
02
Enable for reverse only
000 (short) to 255 (long)
Range and Settings
OPE
00
Display all
0 1
Display only utilized functions (see
table on next page)
02
Display user-selected functions only
(configure with U01 to U12)
03
Data comparison display
04
Basic display
00
Last value dislayed when STR key
was pressed
0 1
D001
02
D002
03
D003
04
D007
05
F001
00
Disable
0 1
Enable
Resulting Non-displayed
Data
Functions (when B37 = 01)
01
A005, A006, A011 – A016, A101 –
A114, C081 – C083, C121 – C123
3–39
SJ700
Inverter
2
Defaults
Run
Mode
FEF2
FUF2
FF2
Edit
FE2
FU2
F2
Lo Hi
(EU)
(USA)
(Jpn)
✘ ✔
0.
0.
0.
✘ ✘
00
00
00
✘ ✘
✘ ✘
✘ ✔
06
06
06
Defaults
Run
Mode
xFE2
xFU2
xFF2
Edit
(EU)
(USA)
(Jpn)
Lo Hi
✘ ✔
04
04
04
✘ ✔
01
01
01
✘ ✔
00
00
00
Notes
[O], [OI], [O2] terminal
functions

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents