Hitachi SJ7002 Series Instruction Manual page 336

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

Func. Code
B003
— Retry wait time before
B004
— Instantaneous power
B005
— Number of restarts on
B006
— Phase loss detection enable
B007
H Restart frequency thresh-
B007
L
B008
— Retry after trip select
B009
— Retry after undervoltage
B010
— Retry count select after
B011
— Retry wait time after trip
B012
— Electronic thermal setting
B212
— Electronic thermal setting
B312
— Electronic thermal setting
B013
— Electronic thermal charac-
B213
— Electronic thermal charac-
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Holding Registers, "B" Group Fine Tuning Functions
Name
R/W
R/W
motor restart
R/W
failure / under-voltage trip
alarm enable
R/W
power failure / under-
voltage trip events
R/W
R/W
old
R/W
R/W
R/W
select
R/W
overvoltage or overcurrent
R/W
R/W
(calculated within the
inverter from current
output)
R/W
(calculated within the
inverter from current
output), 2nd motor
R/W
(calculated within the
inverter from current
output), 3rd motor
R/W
teristic
(Reserved)
R/W
teristic, 2nd motor
(Reserved)
Description
Time delay after a trip condition
goes away before the inverter
restarts the motor
00 .Disable
01 .Enable
02 .Disable during stop and
ramp to stop
00 .Restart 16 times
01 .Always restart
00 .Disable
01 .Enable
When the frequency of the motor
is less than this value, the
inverter will restart at 0 Hz
00 .Always retry after trip
01 .Start with 0 Hz
02 .Start with frequency
matching
03 .Retry after deceleration
and stop with matching
frequency
04 .Start with active
matching frequency
00 .Restart 16 times
01 .Unlimited
1 to 3 (times)
0.3 to 100.0 (seconds)
Range is 0.2 * rated current to
1.2 * rated current
Range is 0.2 * rated current to
1.2 * rated current
Range is 0.2 * rated current to
1.2 * rated current
00 .Reduced torque
01 .Constant torque
02 .Free-setting
00 .Reduced torque
01 .Constant torque
02 .Free-setting
SJ700
Inverter
2
Network Data
Register
Range
hex
dec.
1303h
04867
3 to 1000
1304h
04868
0, 1, 2
1305h
04869
0, 1
1306h
04870
0, 1
1307h
04871
0 to 40000
1308h
04872
1309h
04873
0 to 4
130Ah
04874
0, 1
130Bh
04875
1 to 3
130Ch
04876
3 to 1000
130Dh
04877
200 to
1000
230Ch
08972
200 to
1000
330Ch
13068
200 to
1000
130Eh
04878
0, 1, 2
130Fh
04879
230Dh
08973
0, 1, 2
230Eh
08974
to
to
2501h
09493
B–53
Res.
0.1 sec.
0.01 Hz
times
0.1 sec.
0.1 %
0.1 %
0.1 %