Hitachi SJ7002 Series Instruction Manual page 134

Sj7002 series
Hide thumbs Also See for SJ7002 Series:
Table of Contents

Advertisement

Func.
Code
C015
C016
C017
C018
C019
Intelligent Input
Terminal
Overview
Option
Code
01
02
03
04
05
06
07
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Name/
Description
Terminal [5] active state
Terminal [6] active state
Terminal [7] active state
Terminal [8] active state
Terminal [FW] active state
NOTE: An input terminal configured for option code 18 ([RS] Reset command) cannot be
configured for normally closed operation.
Each of the eight intelligent terminals may be assigned any of the options in the following
table. When you program one of the option codes for terminal assignments C001 to C008, the
respective terminal assumes the function role of that option code. The terminal functions have a
symbol or abbreviation, which we use to label a terminal using that function. For example the
"Reverse Run" command is [RV]. The physical label on the terminal block connector is simply
1, 2, 3, 4, 5, 6, 7, or 8. However, schematic examples in this manual also use the terminal
function symbol (such as [RV]) to show the assigned option. The option codes for C011 to
C019 determine the active state of the logical input (active high or active low).
Summary Table - This table shows all forty-four intelligent input functions at a glance.
Detailed descriptions of these functions, related parameters and settings, and example wiring
diagrams are in
"Using Intelligent Input Terminals" on page
Terminal
Function Name
Symbol
RV
Reverse Run/Stop
CF1
Multi-speed select,
Bit 0 (LSB)
CF2
Multi-speed select,
Bit 1
CF3
Multi-speed select,
Bit 2
CF4
Multi-speed select,
Bit 3 (MSB)
JG
Jogging
DB
External Signal for DC
Injection Braking
Keypad
Range and Settings
SRW OPE
00
NO
Normally open (N.O.)
0 1
NC
Normally closed (N.C.)
00
NO
Normally open (N.O.)
0 1
NC
Normally closed (N.C.)
00
NO
Normally open (N.O.)
0 1
NC
Normally closed (N.C.)
00
NO
Normally open (N.O.)
0 1
NC
Normally closed (N.C.)
00
NO
Normally open (N.O.)
0 1
NC
Normally closed (N.C.)
Input Function Summary Table
Puts the inverter in Run Mode, motor runs reverse
Binary encoded speed select, Bit 0
Binary encoded speed select, Bit 1
Binary encoded speed select, Bit 2
Binary encoded speed select, Bit 3
Puts the inverter in Run Mode, output to motor runs at jog
parameter frequency A038
Applies DC braking during deceleration
SJ700
Inverter
2
Defaults
FEF2
FUF2
FF2
FE2
FU2
F2
(EU)
(USA)
(Jpn)
00
00
00
00
00
00
00
00
00
00
00
00
00
00
00
4–13.
Description
3–51
Run
Mode
Edit
Lo Hi
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔
✘ ✔

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents