Func.
Name
Code
D012
Torque monitor
D013
Output voltage monitor
D014
Power monitor
D015
Cumulative power monitor
D016
Cumulative operation RUN
time monitor
D017
Cumulative power-on time
monitor
D018
Heat sink temperature
monitor
D019
Motor temperature monitor
D022
Component life monitor
D023
Program counter
D024
Program number counter
D025
User monitor 0
D026
User monitor 1
D027
User monitor 2
D028
Pulse counter
D029
Position setting monitor
D030
Position feedback monitor
D102
DC voltage monitoring
D103
BRD load factor monitoring
D104
Electronic thermal overload
monitoring
Description
Estimated output torque value, range is -300.0
to +300.0%
Voltage of output to motor,
range is 0.0 to 600.0V
Input power to inverter, range is 0.0 to 999.9
Displays cumulative input power to inverter;
B079 selects the multiplier for units. Range is
0.0 to 999.9, 1000 to 9999, or 100 to 999
Displays total time the inverter has been in
RUN mode in hours.
Range is 0 to 9999 / 1000 to 9999/
100 to 999 (10,000 to 99,900) hrs.
Displays total time the inverter has had input
power (ON) in hours. Range is:
0 to 9999 / 100.0 to 999.9 /
1000 to 9999 / 100 to 999 hrs.
Displays the temperature of the inverter's heat
sink
Displays motor internal temperature (requires
an NTC thermistor installed in the motor and
connected to [TH] and [CM1]).
Displays estimated life status of DC bus
capacitors and cooling fans
Displays the current program step being
executed when the inverter is operating under
the control of an EZ Sequence program
Displays the EZ Sequence program identifica-
tion number, if defined in the program, when a
program is loaded in the inverter
Displays state of internal EZ Sequence register
User Monitor 0
Displays state of internal EZ Sequence register
User Monitor 1
Displays state of internal EZ Sequence register
User Monitor 2
Displays accumulated pulse count of [PCNT]
intelligent input terminal (option code 74)
Displays absolute position command for
motor shaft in absolute position control mode
Displays absolute position of motor shaft
when in absolute position control mode
Displays the DC Bus voltage
Displays the running average Dynamic
Braking usage ratio (%ED)
Displays the motor electronic thermal
overload estimated temperature ratio. If the
value reaches 100%, the inverter will trip
(E05).
3–7
SJ700
Inverter
2
Units
%
VAC
kW
kW/h
hours
hours
°C
°C
Programs
Program
Pulses
Pulses
Pulses
V
%
%