4–14
Using Intelligent Input Terminals
Wiring Diagram
Conventions
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
The input wiring diagrams in this chapter are examples only. Default and non-default input
terminal assignments are noted throughout; your particular assignments may be different. The
wiring diagrams show the –xFU/–xFR model default [P24]–[PLC] jumper position (U.S./Jpn
versions), as shown below on the left. The common (return) for inputs is [CM1] in this case.
The diagram on the right shows the default jumper position and example input wiring for –xFE
models (Europe version). For this case, the common (return) for inputs is [P24]. Be sure the
jumper position and return terminal used match your application wiring needs.
–xFU/–xFR models (U.S./Jpn versions):
FW
RV
TH
FW
5
4
3
P24
PLC
CM1
Default jumper
position [P24]–[PLC]
and wiring example
(used throughout this
–xFE models (Europe version):
2
1
P24
chapter)
return
FW
RV
TH
FW
5
4
3
2
1
PLC
CM1
Default jumper
position [PLC]–[CM1]
and wiring example
return