B–64
ModBus Data Listing
Func. Code
C123
— [O2] input zero calibration
C130
— Term. [11] ON-delay time
C131
— Term. [11] OFF-delay time
C132
— Term. [12] ON-delay time
C133
— Term. [12] OFF-delay time
C134
— Term. [13] ON-delay time
C135
— Term. [13] OFF-delay time
C136
— Term. [14] ON-delay time
C137
— Term. [14] OFF-delay time
C138
— Term. [15] ON-delay time
C139
— Term. [15] OFF-delay time
C140
— Relay output ON-delay
C141
— Relay output OFF-delay
C142
— Logic output 1 function A
C143
— Logic output 1 function B
C144
— Logic output 1 operator
C145
— Logic output 2 function A
C146
— Logic output 2 function B
C147
— Logic output 2 operator
C148
— Logic output 3 function A
C149
— Logic output 3 function B
C150
— Logic output 3 operator
C151
— Logic output 4 function A
C152
— Logic output 4 function B
C153
— Logic output 4 operator
C154
— Logic output 5 function A
C155
— Logic output 5 function B
Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Holding Registers, "C" Group Intelligent Terminal Functions
Name
R/W
R/W
(Reserved)
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
time
R/W
time
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
R/W
Description
0. to 9999., 1000 to 6553
(10000 to 65530)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
0.0 to 100.0 (seconds)
All programmable output
functions available (except
LOG1 to LOG6)
00..AND
01..OR
02..XOR (exclusive OR)
All programmable output
functions available (except
LOG1 to LOG6)
00..AND
01..OR
02..XOR (exclusive OR)
All programmable output
functions available (except
LOG1 to LOG6)
00..AND
01..OR
02..XOR (exclusive OR)
All programmable output
functions available (except
LOG1 to LOG6)
00..AND
01..OR
02..XOR (exclusive OR)
All programmable output
functions available (except
LOG1 to LOG6)
Network Data
Register
Range
hex
dec.
147Fh
05247
0 to 65530
1480h
05248
to
to
1485h
05253
1486h
05254
0 to 1000
1487h
05255
0 to 1000
1488h
05256
0 to 1000
1489h
05257
0 to 1000
148Ah
05258
0 to 1000
148Bh
05259
0 to 1000
148Ch
05260
0 to 1000
148Dh
05261
0 to 1000
148Eh
05262
0 to 1000
148Fh
05263
0 to 1000
1490h
05264
0 to 1000
1491h
05265
0 to 1000
1492h
05266
1493h
05267
1494h
05268
0, 1, 2
1495h
05269
1496h
05270
1497h
05271
0, 1, 2
1498h
05272
1499h
05273
149Ah
05274
0, 1, 2
149Bh
05275
149Ch
05276
149Dh
05277
0, 1, 2
149Eh
05278
149Fh
05279
Res.
1
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.
0.1 sec.