Clearwater Tech - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.clrwtr.com - Email: info@clrwtr.com
Trip Factor Code, HIGH order
Code
Name
0
No trip
1
Over current event while at constant
speed
2
Over current event during deceleration
3
Over current event during acceleration
4
Over current event during other condi-
tions
5
Overload protection
6
Braking resistor overload
7
Over voltage protection
8
EEPROM error
9
Under-voltage error
10
CT (current transformer) error
11
CPU error
12
External trip
13
USP
14
Ground fault
15
Input over-voltage
16
Instantaneous power failure
20
Inverter thermal trip with low fan
speed
21
Inverter thermal trip
23
Gate array error
24
Phase failure detection
25
Main circuit error
30
IGBT error
35
Thermistor
36
Brake error
37
Emergency stop
38
Low-speed overload protection
43
Easy sequence error (invalid instruc-
tion)
44
Easy sequence error (invalid nesting
count)
45
Easy sequence execution error 1
50 to 59
Easy sequence user trip 0 to 9
60 to 69
Expansion card #1 error 0 to 9
70 to 79
Expansion card #2 error 0 to 9
SJ700
Trip Factor Code, LOW order (inverter status)
Code
Name
0
Reset
1
Stop
2
Deceleration
3
Constant speed
4
Acceleration
5
Run Command active with 0 Hz speed
reference
6
Starting
7
DC braking
8
Overload restriction
9
SON or FOC operation in progress
B–41