Installation and commissioning

CAUTION!
Risk of machine
damage!
CAUTION!
Risk of machine
damage!
DANGER!
Risk of electrocution!
BASCJ_EN
V01 | 02.2011
Installation and commissioning

Setting up the coffee machine

Location

The location where the coffee machine is set up must meet the conditions specified be-
low. If these conditions are not ensured, the coffee machine may become damaged.
The following conditions absolutely must be met:
The installation surface must be stable and level so that is does not become deformed un-
der the weight of the coffee machine.
Do not set up the coffee machine on hot surfaces or close to ovens.
Set up the coffee machine in such a way that it can be monitored by trained personnel at
any time.
Route the necessary supply connections to within 1 m of the machine location according
to the on-site installation plans.
Maintain the following clearances for maintenance work and operation:
Allow enough space above the machine to refill beans.
Leave a clearance of ±35 cm on the left side.
Leave a clearance of min. 15 cm from the rear of the machine to the wall (air circula-
tion).
Leave a clearance of min. 250 mm above the machine (needed to remove the brewing
unit for cleaning and maintenance).
Comply with all applicable local kitchen regulations.

Ambient conditions

The location where the coffee machine is set up must provide the ambient conditions
specified below. If these conditions are not ensured, the coffee machine may become
damaged.
The following conditions absolutely must be met:
Ambient temperature of +10 °C to +40 °C (50 °F to 104 °F)
Relative humidity of max. 80 % RH
The coffee machine is designed for indoor use only. Do not use in the open and never ex-
pose to the weather (rain, snow, subzero temperatures).
If the coffee machine was exposed to subzero temperatures:
► Contact customer service before commissioning.

Power supply

Conditions

The electrical power supply must be connected in accordance with the applicable regulations
(VDE 0100) and the regulations of the country of installation. Type of power cable at least H
07 RN-F. The voltage specified on the serial plate must match the supply voltage at the instal-
lation location.
Danger of electric shock!
The following instructions absolutely must be complied with:
The phase must be fused at the ampere value specified on the serial plate.
It must be possible to disconnect the device from the mains power supply at all poles.
Never operate a device with a damaged power cord. Have a defective power cord or plug
replaced immediately by a qualified service technician.