Safety Vision SVR-4100 User Manual page 41

Advanced mobile digital video recorder
Table of Contents

Advertisement

39
low voltage Protection
The Low Voltage Protection menu
controls the voltage threshold before the
SVR-4100 shuts down automatically to
protect itself.
Use the remote control to configure the
following:
ENABLE: Select ON to enable voltage
protection.
LOW VOLTAGE: Enter the minimum
voltage, in volts, that the SVR-4100
can receive before it automatically
disconnects from the CMS or shuts
down.
VOLTAGE OF START: Enter the voltage,
in volts, that the vehicle typically drops
to during startup (the ignition key is
turned).
INTERNAL TIME FOR CMS: Select the
time, in minutes, that the SVR-4100 can
continue to receive the voltage indicated in the VOLTAGE field before disconnecting
from the CMS. SHUT DOWN DELAY: Select the time, in minutes, that the SVR-4100
can continue to receive the voltage indicated in the LOW VOLTAGE field before
automatically shutting down.