Conversion To Another Type Of Gas; Jet Table - Miele CS 1011 G Operating And Installation Instructions

Table of Contents

Advertisement

Conversion to another type of gas

,
Connection to the gas supply, or
conversion from one type of gas to
another, should only be undertaken
by an approved and registered gas
installer in strict accordance with
current local and national safety and
building regulations.
When converting to a different type of
gas, the main burner jets and the small
burner jets have to be changed.
Nominal ratings
Nominal ratings for ULPG are based on
propane gas.
Nominal rating at maximum setting
Gas type
NG
ULPG
Nominal rating at low setting
Gas type
NG
ULPG
Nominal rating at minimum setting
Gas type
NG
ULPG
44
Screw in the new jets according to the
following table.

Jet table

NG
ULPG
The jet markings refer to 1/100 mm of
the jet diameter.
The small jet C 1.10 is marked 1B.
MJ/h
15
15
MJ/h
5.99
5.89
MJ/h
0.66
0.66
Main jet
Small jet
C
C
1.8 / 34
1.10 (1B)/
0.42
1.05 / 7
0.68 / 0.25

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents