Conversion To Another Type Of Gas; Jet Table - Miele KM 3034-1 Installation Manual

Table of Contents

Advertisement

Conversion to another type of gas

Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an authorised and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed. Disconnect the cooktop
from the electricity supply and turn
off the gas supply.
11135230-03

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
NG
Auxiliary
burner
Semi-rapid
burner
Rapid burner
Wok burner
ULPG
Auxiliary
burner
Semi-rapid
burner
Rapid burner
Wok burner
Main jet
Small jet
0.90
1.10
1.43
2x 1.27 / 0.90
0.52
0.66
0.81
2x 0.70 / 0.46
0.52
0.52
0.60
0.44
0.23
0.36
0.44
0.25