Conversion to another type of gas

Risk of explosion due to an
incorrect conversion.
If the conversion to another type of
gas is carried out incorrectly, it may
result in gas leakage.
Conversion from one type of gas to
another must only be undertaken by
an authorised and registered gas
installer in strict accordance with
current local and national safety and
building regulations. The installer is
responsible for ensuring that the
appliance functions correctly when
installed. Disconnect the cooktop
from the electricity supply and turn
off the gas supply.

Jet table

The jet markings refer to a ¹/₁₀₀ mm
bore diameter.
The table below shows the jet sizes in
mm.
Natural gas H
Auxiliary burner
Semi-rapid burner
Rapid burner
Wok burner
Liquid gas
Auxiliary burner
Semi-rapid burner
Rapid burner
Wok burner
60
Main jet
Small jet
0.90
0.52
2x 1.10
0.52
1.43
0.60
1.27 / 0.90
0.44
0.52
0.23
2x 0.66
0.36
0.81
0.42
0.70 / 0.46
0.25

Changing the jets

 Disconnect the cooktop from the
electricity supply and turn off the gas
supply.
When converting to another type of
gas, both the main and small jets
need to be changed.