Operation
Operating Instructions 610/630 - 00.0 - 05/2014
Fig. 23: Water level in the maintenance unit
6
4
2
0
(1) – Filter element
(2) – Water separator
Checking the water level:
1. Check the water level every day.
Important: The condensed water must not rise to the level
of the filter element (1).
Drain water as required:
1. Switch off the sewing machine at the main switch.
2. Place the collection tray under the drain screw (3).
3. Disconnect the compressed air hose from the compressed
air supply.
4. Unscrew the drain screw (3) completely.
5. Allow water to drain into the collection tray.
6. Re-tighten the drain screw (3).
7. Connect the compressed air hose to the compressed air supply.
8. Switch on the sewing machine at the main switch.
ATTENTION
Machine damage possible due to excess water.
Excess water can cause damage to the machine.
Check the water level every day and drain the condensed
water if there is too much water in the water separator.
8
10
1
2
3
(3) – Drain screw