Operation
Operating Instructions 610/630 - 00.0 - 05/2014
ATTENTION
Malfunctions possible due to machine contamination.
Sewing dust and thread remains can impair the operation
of the machine.
Clean the machine at regular intervals as described
in the instructions.
Observe the cleaning intervals set out in the table. In the case
of materials with a high lint content, the machine must be
cleaned more frequently.
Places that need to be cleaned particularly thoroughly
and cleaning intervals
Machine area
• Area under the throat plate
• Area around the looper
• Area around the thread pick-up disk
• Thread cutter
• Area around the needle
• Air inlet openings on the motor fan sieve
• Oil pan
Cleaning steps
1. Switch off the power supply at the main switch.
2. Remove any sewing dust and thread remains using
a compressed-air pistol or a brush.
3. Remove any sewing dust and cutoffs from the oil pan.
ATTENTION
Possible damage to the paintwork from solvent-based
cleaners.
Solvent-based cleaners damage the paintwork of the machine.
Use only solvent-free substances when wiping down the
machine.
Cleaning interval
Every 8 operating
hours
Every 40 operating
hours