Programming The Pccchip2 And Vmechip2 - Motorola MVME167 Series Installation Manual

Single board computer
Hide thumbs Also See for MVME167 Series:
Table of Contents

Advertisement

Table 3-15. RTC Initialization Procedure
Step
Board Mode
1
Allow 167Bug to boot up normally.
2
At the
167-Bug>
TIME to display the current date and
time of day.
3
At the
167-Bug>
set the time and date. Use the following command line structure:
SET [<MMddyyhhmm>]|[<+/-CAL>;C]
For example:
167-Bug>SET 0522961037
WED May 22 10:37:00.00 1996
167-Bug>
Where the arguments are: MM=month, dd=day of the month, yy=year,
hh=hour in ÒmilitaryÓ (24 hour) time, and mm=minutes.

Programming the PCCchip2 and VMEchip2

See System Considerations below, and refer to Memory Maps on
page 2-24, and the Single Board Computer Programmer's Reference
Guide for details on your particular system environment.
Action
Stop the auto-boot sequence by
pressing the <BREAK> key. (If the
system has already started and failed
a conÞdence test in system mode, you
should be in the debugger menu).
prompt, enter
Select (3) from the debugger menu to
get the debugger prompt.
prompt, use the SET command to initialize the RTC and to
<Return>
Installing the Hardware
System Mode
3
3-25

Hide quick links:

Advertisement

Table of Contents
loading