Configure and Environment Commands
A
A-2
Example: to display the current contents of the board information
block.
cnfg
167-Bug>
Board (PWA) Serial Number = "000000061050"
Board Identifier
Artwork (PWA) Identifier
MPU Clock Speed
Ethernet Address
Local SCSI Identifier
Optional Board 1 Artwork (PWA) Identifier
Optional Board 1 (PWA) Serial Number
Optional Board 2 Artwork (PWA) Identifier
Optional Board 2 (PWA) Serial Number
167-Bug>
Note that the parameters that are quoted are left-justified character
(ASCII) strings padded with space characters, and the quotes (") are
displayed to indicate the size of the string. Parameters that are not
quoted are considered data strings, and data strings are right-
justified. The data strings are padded with zeroes if the length is not
met.
In the event of corruption of the board information block, the
command displays a question mark "?" for nondisplayable
characters. A warning message (
is also displayed in the event of a checksum failure.
Checksum Error)
Using the I option initializes the unused area of the board
information block to zero.
Modification is permitted by using the M option of the command.
At the end of the modification session, you are prompted for the
update to Non-Volatile RAM (NVRAM). A
made for the update to occur; any other response terminates the
update (disregards all changes). The update also recalculates the
checksum.
Be cautious when modifying parameters. These parameters are
initialized by the factory, and correct board operation relies upon
these parameters.
= "MVME167-03
"
= "01-W3826B03A
"
= "2500"
= 08003E20A867
= "07"
= "
= "
= "
= "
WARNING: Board Information Block
response must be
Y
"
"
"
"