GE D20MX Instruction Manual page 18

Hide thumbs Also See for D20MX:
Table of Contents

Advertisement

License
D20MX
Group
Application ID
A068N
A078N
A083-0
A088-0
A101-0N
A104-0N
001
A113N
A118
A121-0
A123-0
A131-0
A135-0
A161-0
A184-0
001
A185-0N
A186-0
A193-0
001
A194-0
A195-0
18
Base D20 Classic
Application Name
Application Version †
311
Modbus DPA
610
SEL Gateway DCA for
D20MX
342
Calculator DTA
203
Substation Maintenance
DTA
906
IEC 870-5-101 DPA for
D20MX
124
Alarm Grouping DTA for
the D20MX
301
PSR DCA for D20MX
103
Failover DTA
200
Automatic Frequency
Selection DTA
111
NGC General DTA
131
MODBUS TCP/IP DCA
110
MODBUS TCP/IP DPA
301
Secondary Master Trip/
Close DTA
120
General Alarm DTA
303
W18979 DPA for D20MX
213
Western Power
Distribution (WPD) DTA
302
Top of the Hour Analog
Averaging DTA
101
Cooper 2179 DCA
110
Redundant I/O DTA
GE INFORMATION
CHAPTER 1: BEFORE YOU START
Description
Capable of communicating with one or more
master stations using the MODBUS protocol
(RTU & ASCII modes).
A sub-master within a SCADA system,
controlling SEL relay equipment using SEL's
ASCII character-based relay protocol
Convenient and flexible soft logic utility that
can perform applications such as substation
level interlocking, feeder interlocking, and
converting digital inputs to control outputs for
driving a map board
Allows status and analog input values to be
suppressed for maintenance purposes.
Communicate with one or more hosts using the
IEC 60870-5-101/104 (T101) protocol. Has the
ability to function as several distinct IEC 60870-
5-101/104 RTUs. Supports the unbalanced
version of the data link.
Provides DI points each representing a group
alarm. The group alarm is generated when the
number of DI points in the alarm state exceed
the group threshold value.
Programmable Synchrocheck Relay (PSR) DCA
acts as a data concentrator for several remote
PSRs. The DCA and remote PSRs function as a
remote synchronous closure controller.
Allows configurable combination of control
requests to result in a failover or switchover of
a redundant system.
Provides AI points each derived from an
Automatic Selection Method (ASM). An ASM
selects the highest priority valid frequency
measurement from a group of AI points.
Generates control lockout indications, digital
input suppression or unsupression indications,
and control active indications.
Provides an interface to Sub-Remote Units
(SRUs) using the MODBUS protocol over the
TCP/IP communication layer.
Provides communications with one or more
master station using the MODBUS protocol
over TCP/IP communication layer.
Translates control requests into conventional
trip/close operations in conjunction with
secondary control operations to be used as a
Secondary Master Trip or Close.
Takes several alarms and groups them
together under one General Alarm.
Emulates the Landis & Gyr 8979 RTU.
Communicates with multiple master stations,
over redundant communication lines.
Calculates power from monitored voltage,
current, and phase angle. Also, performs time
integrated analog averaging, relative to the top
of the hour.
Performs time integrated analog averaging,
relative to the top of the hour.
Monitors and controls Cooper devices using
the Cooper 2179 protocol.
Provides I/O point redundancy.
D20MX INSTRUCTION MANUAL