D20MX applications

License
D20MX
Group
Application ID
Common Application Definitions
001
A009N
001
A017N
001
A018
001
A023N
A026-1
A027N
A030
001
A033-5N
A035
001
A036N
001
A041-1
A048
A059-0N
D20MX INSTRUCTION MANUAL
Table 2 lists the applications included in the D20MX firmware.
* An Application ID containing an "N" (e.g., A009N) signifies a unique application definition
for the D20MX.
† The D20MX version of the application is based on this D20 classic application version.
However, the D20MX version is not identical to the D20 classic version due to minor
changes to improve the robustness and security of the original application.
‡ The version of B009 in SAN0002 is actually based on D20 classic application version 401
but modified to be compatible with the version 310 application definition version.
The version of B021 in SAN002 is actually based on D20 classic application version 991
Ф
but modified to be compatible with the version 912 application definition version.
Table 2: D20MX applications
Base D20 Classic
Application Name
Application Version †
805
PG&E DPA for D20MX
131
Distributed Network
Protocol V1.00 DCA for
D20MX
120
Quantum Meter Scanner
DCA
423
CDC Type I DPA for D20MX The CDC Type I DPA emulates a CDC Type I RTU
321
Communication
Watchdog DTA
832
SOE Logger DTA for D20MX The Sequence-of-Events Logger DTA processes
300
Accumulator Freeze DTA
211
TEJAS V DPA for D20MX
211
Analog Reference DTA
421
ProLogic Executor DTA for
D20MX
116
Proportional Integral
Derivative Control DTA
210
Status Combination DTA
911
Modbus DCA for D20MX
GE INFORMATION
Description
Pacific Gas and Electric (PG&E) data-processing
application (DPA) for remote terminal units
(RTUs).
Distributed Network
Protocol (DNP) V1.0 Data Link Application.
Required by the Quantum Meter Scanner DCA.
The Quantum Meter Scanner DCA obtains data
from one or more Quantum Meters via the DNP
interface.
Reports on the state of communications
between the RTU and a remote device (Data
Translation Application).
sequence of events (SOEs) from any sub-set of
the system digital input and/or analog input
points.
Detects system status point changes and
system accumulator point freezes.
Emulates a remote terminal unit utilizing the
(Valmet/Metso/Telvent) TEJAS V
communication protocol.
Monitors analog input points and provides the
system database with pseudo analog values
that represent either correctly functioning
analog input hardware (good reference value),
or failed analog input hardware (bad reference
value).
Provides user programmable soft logic
automation functionality.
The Proportional, Integral and Derivative (PID)
DTA uses the generally-accepted industry
standard for control of closed loop processes.
Provides one ore more DI points, each of which
provides an event-driven logical OR of a set of
mapped system DI points.
Acts as a data concentrator for one or more
Sub-Remote Units (SRUs) using the MODBUS
communication protocol (RTU & ASCII modes).
17