Download Print this page
GE ATS1290 Manual
Hide thumbs Also See for ATS1290:

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 1

Quick Links

EN
FR
NL
IT
DA
FI
DE
S
R
A
B
1
2006 GE Security B.V.
All rights reserved.
www.gesecurity.net
ATS1290
IADS DGP
V
T
A
B
A
B
2
3
U
1055375
07/2006

Advertisement

loading

Summary of Contents for GE ATS1290

  • Page 1 ATS1290 IADS DGP 2006 GE Security B.V. 1055375 All rights reserved. 07/2006 www.gesecurity.net...
  • Page 2 Introduction In the point identification solution, only I/O modules (integrated and The ATS1290 is an interface between the ATS LAN bus and an IADS bus standalone I/O) are recommended. In this configuration conventional (Intelligent Addressable Device System bus). It provides two-wire detectors with additional IADS modules (AD011/AD111) are used.
  • Page 3: Recommended Cable Type

    Data + power for all addressable detectors 1st DGP Internal module DIP switch setting on The ATS1290 can support 16 detectors. For some modules, 2 inputs are address (e.g. EV435-AD) address internal module necessary, and therefore the expanded addressing mode could be used to stay into the range of 32 addresses on the ATS1290.
  • Page 4: Montage De L'unité

    When modules share the same address by accident, the text "Multiple modules" is shown. Check the Le DGP ATS1290 fait office d’interface entre le bus RS485 de la address settings of the modules to cancel the fault.
  • Page 5 Alimentation des détecteurs - 2 fils. Déporté 1 x 40 m 1 x 80 m L’ATS1290 supporte jusqu’à 32 entrées dans cette configuration. Les détecteurs doivent être alimentés par une alimentation séparée. 16 x 10 m 16 x 20 m C’est une solution optimisée pour alimentation externe.
  • Page 6 Appuyez sur 0 puis ENTER (ENTREE) pour sortir. Appuyez sur le numéro le menu ATS1290. Pour plus d’informations sur les réglages de zone puis ENTER (ENTREE) pour obtenir des informations détaillées supplémentaires possibles d’un périphérique, reportez-vous au manuel...
  • Page 7 ATS1290 IADS DI Inleiding De ATS1290 DI is een interface tussen de ATS systeem databus en de IADS databus (Intelligent Adressable Device databus). De ATS1290 DI maakt twee-draads communicatie in twee richtingen met maximaal 32 afzonderlijk geadresseerde IADS modules mogelijk. De ATS1290 DI...
  • Page 8 Indien voor de IADS bus een afgeschermd kabeltype wordt gebruikt, het DI-nummer. Stel het gewenste DI-nummer in mag deze afscherming niet via de ATS1290 DI aardlip, PID- of PID+ behulp van de dipswitches zoals aangegeven in figuur aansluiting geaard worden. Het aansluiten van de afscherming zal...
  • Page 9 ATS1290 IADS DI. IADS bus 0.5 mm 1 mm Om dit te realiseren is de ATS1290 IADS DI uitgerust met een jumper 1 x 800 m 1 x 1600 m (JP2, Fig. ). Als u deze jumper enkele seconden kortsluit wordt de inleermodus gestart, in deze mode worden de modules geregistreerd.
  • Page 10: Montaggio Dell'unità

    Bij waarde-presentatie voert u een decimale waarde in tussen 0 en 255. Bij bit-presentatie drukt u op het bitnummer (1 tot 8) om de bit L’ATS1290 è un’interfaccia tra il bus dati dell’ATS e un bus IADS van 0 naar 1 te schakelen, of andersom. Raadpleeg de handleiding van (Intelligent Addressable Device System bus).
  • Page 11 • Alimentazione per I sensori – 2 fili. L’alimentazione supplementare per sensori tradizionali non è L'ATS1290 supporta 32 ingressi in questa configurazione. I sensori devo presa in considerazione nel calcolo. essere alimentati da un'alimentazione separata. Impostazione dell’indirizzo del dispositivo IADS Questa modalità...
  • Page 12 I dispositivi IADS devono essere riconosciuti dal concentratore IADS Nel caso di dispositivi che per errore condividono lo stesso indirizzo, ATS1290 per poter trasmettere informazioni di stato o per poter essere viene mostrata l’indicazione "Multiple devices" [Dispositivi multipli]. Per configurati tramite il concentratore IADS.
  • Page 13 I/O). I denne konfuguration benyttes standard detektorer sammen med seperate IADS moduler (AD011/AD111) ATS1290 er et interface mellem ATS bussen og en IADS-bus (Intelligent Addressable Device System bus). IADS-DGP’en muliggør totrådet Denne konfuguration kræver en 4-leder forbindelse: tovejskommunikation med op til 32 individuelt adresserede IADS- •...
  • Page 14 2 x 2 x 0.5 mm via IADS DGP’en. Antal ledere 1 + 1 2 + 2 For at lette denne proces er ATS1290 IADS DGP’en forsynet med en jumper (JP2, fig. ). Hvis denne jumper kortsluttes med en IADS bus 0.5 mm 1 mm skruetrækker i et par sekunder, starter indlæsningstilstanden, hvor...
  • Page 15 0 og 1. Oplysninger vedrørende tilgængelige indstillinger finder System") mahdollistaa kaksisuuntaisen kahden johtimen yhteyden du i vejledningen til den pågældende enhed. 32 IADS-laitteeseen, joilla kullakin on oma osoite. ATS1290 on Tryk på ENTER for at gå videre til næste placering. tarkoitettu liitettäväksi...
  • Page 16 Data + tehonsyöttö ilmaisimille. Osoitteellisen laitteen osoiteasetus on suoraan yhteydessä niihin ATS1290 tukee 16:ta tai 32:ta ilmaisinta. Jotkut ilmaisimet (EV435AM- silmukan ja lähdön numeroihin, jotka laitteelle on ohjelmoitu AD) voivat käyttää kahta osoitetta). Jos osoiteväylä on pitkä ja siinä on keskuslaitteessa.
  • Page 17 ASMOKE Analogiset osoitteelliset savuilmaisimet enemmän lähtöjä. I/O-laitteet (osoitepäätteet) Osoitelaitteiden tunnistaminen Jos järjestelmä ei tunnista laitetta, sen kohdalla näkyy teksti "Not ATS1290-osoitekeskittimen pitää tunnistaa osoitelaitteet, ennen kuin used". Laiteluokan edessä oleva merkki "$" ilmaisee, että laitteen laite lähettää tilatietoja ohjelmoida asetukset poikkeavat oletusasetuksista. Jos useille laitteille on osoitepäätekeskittimen avulla.
  • Page 18 ± 5 %) Einführung IADS-tehonsyöttö (CON2) 9.9–13.2 V +ylimääräiset Die ATS1290 AME ist eine Schnittstelle zwischen dem ATS LAN-Bus und datapulssit einem IADS-Bus (Intelligent Addressable Device). Sie realisiert eine Suurin IADS-lähtövirta 154 mA (suurin kuormitustaso 512) bidirektionale Zweidraht-Kommunikation mit bis zu 32 einzeln (jännitteellä...
  • Page 19 Anz. Drähte 1 + 1 2 + 2 • Spannung für Detektoren – 2 Drähte. Das ATS1290 unterstützt in dieser Konfiguration bis zu 32 Eingänge.Für IADS-Bus 0.5 mm 1 mm die Spannungsversorgung der Melder ist ein separates Netzteil In Reihe...
  • Page 20 Modulkategorie gibt dass Modul Um dies zu vereinfachen, besitzt die IADS-AME ATS1290 eine Standardeinstellungen abweichende Einstellungen hat. Wenn die Steckbrücke (JP2, Abb. ). Wenn Sie diese Steckbrücke für einige Module zufällig dieselbe Adresse verwenden, wird der Text "Mehrere Sekunden mit einem Schraubenzieher überbrücken, dann wird der...
  • Page 21 Technische Daten Versorgungs- 10.5 – 13.8 V spannung (CON1) Stromaufnahme 53 mA (keine IADS-Module angeschlossen) (bei 13.8 V ± 5%) IADS-Datenbus 9.9 – 13.2V + zusätzliche Versorgungs-spannung Datenimpulse (CON2) Max. IADS 154 mA (max. Gerätelast 512) Ausgangsstrom (bei 13.2 V ±...