Voltage related system shutdown

Message
System shutoff due to x current over
max value (level-critical; system drawing
too much current on voltage x bus)
System shutoff due to x V over voltage
(level-critical; system shutoff due to x
supply over voltage)
System shutoff due to x V under voltage
(level-critical system shutoff due to x supply
under voltage)
System shutoff due to VRM x over
voltage
System shutoff due to excessive (< 240
VA) loading

Temperature related system shutdown

Message
System shutoff due to board over
temperature (level-critical; board is over
temperature)
System shutoff due to CPU x over
temperature (level-critical; CPU x is over
temperature)
System shutoff due to CPU x under
temperature (level-critical; CPU x is under
temperature)
System shutoff due to DASD temperature
(sensor x) (level-critical; DASD area
reported temperature outside recommended
operating range)
System shutoff due to high ambient
temperature (level-critical; high ambient
temperature)
System shutoff due to system board
under temperature (level-critical; system
board is under temperature)

DASD checkout

Message
Hard drive x removal detected
(level-critical; hard drive x has been
removed)
Action
v See "Power checkout" on page 31.
1. Check the power-supply connectors
2. Power supply.
1. Check the power-supply connectors.
2. Power supply.
v Replace VRM x.
1. See "Power checkout" on page 31.
2. Cycle ac on/off.
Action
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 41.
2. Replace board.
1. Ensure that the system is being properly cooled; see "System
reliability considerations" on page 41.
2. Replace microprocessor x.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
v Ensure that the system is being properly cooled; see "System
reliability considerations" on page 41.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
v Ambient temperature must be within normal operating
specifications; see "Features and specifications" on page 4.
Action
v Information only, take action as appropriate.
115
Symptom-to-FRU index