Error code/symptom
00180500 (PCI option ROM checksum
error.)
00180600 (PCI device BIST failure. PCI
bridge error.)
00180700 (PCI device no responding.)
00181000 (General PCI error)
I9990650 (AC power has been restored)
POST (ISPR) error procedures
Use the ISPR error procedures to help you solve ServeRAID problems. A complete
list of error codes is listed at "ServeRAID error codes" on page 111.
Note: Where the ISPR Error Procedures refer to a hard disk drive backplane, see
EF10 (Default ISPR)
1. No ISPR error present.
9ZXX thru BZXX (SCSI bus error caused by cables, termination, or defective
drives.)
1. Isolate the SCSI subsystem from the controller by disconnecting all hard disk
2. If ISPR error is EF10 after disconnecting cables:
FRU/action
1. PCI adapter
2. System board
1. Run the Configuration/Setup Utility program.
2. Adapter.
3. System board.
1. System board
2. PCI adapter
v Adapter
v System board
1. Check cable.
2. Check for interruption of power.
3. Power cable.
the chapter of this publication that concerns field replaceable units.
drive cables from the suspect adapter, and restart the computer.
CAUTION:
Do not press F5. Doing so changes the configuration of the server.
If an ISPR error is still present, perform the following actions until the error is no
longer present:
a. Reseat the controller
b. Replace the controller
Notes:
a. SCSI channel cable details, if any, appear elsewhere in this publication.
b. The adapter/controller detects a configuration change. Do not select Save
Changes. Instead, press F10 to bypass any options to this effect.
a.
Identify which channel is causing the error by the second digit (Z) of the
original ISPR code as indicated in the following table:
Note: ServeRAID-4H controllers have four channels; ServeRAID-4L and
-4Lx controllers have only one channel; and ServeRAID-4M and -4Mx
controllers have two channels. ServeRAID-5i controllers have no
channels. The ServeRAID-5i uses the channel connectors of the
integrated SCSI controller of the server.
109
Symptom-to-FRU index