Honda EP3 Service Manual page 222

2002; 2003
Table of Contents

Advertisement

7 .
Disconnect the radiator fan motor 2P connector.
Check for continuity between the No. 1 terminal of
the radiator fan relay 4P socket and the No. 2
terminal of the radiator fan motor 2P connector.
RAOIATOR
FAN REI-AY 4P SOCKET
Terminal side of
female terminals
RADIATOR FAN MOTOR 2P CONNECTOR
ls thete continuity?
YES-Go to step 8.
NO Repair open in the wire between the under-
hood fuse/relay box and the radiator fan motor 2P
connector terminal No. 2,I
8. Check for continuity between the No, 1terminal of
the radiator fan motor 2P connector and bodv
g rou nd.
RADIATOR F
W i r e s i d e o f f e m a l e t e r m i n a l s
ls there continuity?
YES Replace the radiator fan motor.l
NO Check for an open in the wire between
radiator fan motor 2P connector terminal No. 1 and
body ground. lf the wire is OK, check for a poor
g r o u n d a t G 3 0 1 . 1
AN MOTOR 2P CONNECTOR
rftr
T-
Y
9 .
1 0 .
Reinstall the radiator fan relay.
Disconnect the radiator fan switch 2P connector.
Connect the No. 1 and No. 2 terminals, of the
radiator fan switch 2P connector with a jumper wire.
RAOIATOR FAN SWITCH
2P CONNECTOR
1 1 .
5\-
\
I J U M P E R
f-;
'fl
I wrRE
\r--
Wire side of female terminals
Does the radiator fan run?
YES- Replace the radiator fan switch.l
N O - G o t o s t e p 1 2 .
Remove the jumper wire, and measure the voltage
between the No, 2 terminal of the radiator fan
switch connector and body ground,
RADIATOR FAN SWITCH
2P CONNECTOR
ls there battery voltage?
YES Check for an open in the wire between
radiator fan switch 2P connector terminal No. 1 and
body ground. lf the wire is OK, check for a poor
g r o u n d a t G 3 0 1 . 1
NO Repair open in the wire between the radiator
fan switch terminal No. 2 and the under-hood
fuse/relay box.l
1 0 - 1 5

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

2002 ep32003 ep3

Table of Contents