2gig Technologies Go!Control 2GIG-CNTRL2 Installation & Programming Instructions page 36

Wireless security system
Hide thumbs Also See for Go!Control 2GIG-CNTRL2:
Table of Contents

Advertisement

Installer Programming
Q-44
Select lock installer programming (0-2)
DEFAULT: Disabled (0)
The installer programming lockout feature is provided to prevent takeovers. The
Control Panel can be set to limit an installer's access to programming questions
after a period of 48 hours. The 48 hour lockout timer starts when the installer exits
system confi guration mode.
Three options are available: unlimited full access to programming (no lockout),
limited access to programming after 48 hours, or no access to programming after
48 hours.
• The default (0) selects unlimited full access to programming (no lockout).
• To deny access to programming after 48 hours,
select no access to programming (1).
• To select limited access to programming after 48 hours, select (2). After the
system has run for 48 hours, installer will be able to view, but not change,
the Central Station phone number, Central Station account number,
lock installer programming, download ID, and default lockout fi elds.
After the 48 hour lockout timer has locked out the system, the timer can be reset
through the GSM radio or PC downloader by remotely setting this question Q-44
to (0) or (2). Setting the option to (0) or (2) will restart the 48 hour lockout timer.
Q-45
Select lock default programming (0-2)
DEFAULT: Default all (0)
The Control Panel may be able to be hard reset (or soft reset from the Installer
Toolbox) to its factory default values depending on the value entered for this
programming question.
The Control Panel is hard reset by pressing and holding the
buttons while applying power to the Control Panel.
The default lockout feature is provided to prevent takeovers. Three options are
available: allow default of all options, allow default of some but not all options, not
allow default of any options.
• The default setting of default all (0) allows resetting the Control Panel to all
its factory defaults.
• To allow resetting the Control Panel to all its factory defaults except the
Central Station phone number, Central Station account number, lock installer
programming, download ID, and default lockout fi elds, select (1).
• To deny hard and soft resetting of the Control Panel, select default none (2).
If option (1) or (2) is selected, the option will take effect after the system has run
for 48 hours. This allows the installer to go back and make changes if required.
Q-46
Select trouble doesn't sound at night (0-1)
DEFAULT: Enabled (1)
The Control Panel will sound trouble beeps caused by AC loss, system low
battery, sensor low battery or RF supervision, failure to communicate, Control
Panel tamper while disarmed, and GSM radio faults.
To prevent annoying the subscriber, the system can be set to suppress trouble
beeps from sounding from 10 pm to 9 am. The trouble(s) will still be displayed and
immediately reported to the Central Station, and can be acknowledged, but they
won't sound beeps until after 9 am.
If the trouble condition(s) self-clear or are acknowledged before 9 am, no trouble
beeps will sound after 9 am (the conditions will still be recorded in the event
log).
• The default (1) suppresses trouble beeps from 10 pm to 9 am.
• To allow trouble beeps at any time, select disabled (0).
✓ NOTE: For UL985 Installations, this feature must be disabled.
34
Q-47
Select trouble resound after holdoff (0-7)
DEFAULT: Disabled (0)
Fire and CO sensors are required to re-sound trouble beeps every four hours
until the trouble is resolved, even if the trouble is acknowledged at the Control
Panel. The Control Panel can be set to delay re-sounding these types of trouble
beeps for 1-7 days.
✓ NOTE: This feature is not allowed in UL 985 installations. The
setting must be disabled (0) in this grade of installation.
• The default (0) allows trouble beeps for CO and fi re sensors
to re-sound every four hours after being acknowledged.
• To delay re-sounding trouble beeps for CO
and fi re sensors, select (1-7) days.
Q-48
Enter download csid (6 digits)
DEFAULT: 000000
The system supports a 6-digit CSID code that is used for remote telephone
programming of the Control Panel. This code is verifi ed when the Control Panel
connects with the downloading software. If the CSID code doesn't match the
downloading software, the Control Panel will deny the connection.
• The CSID code can be entered manually with this programming question.
• If this fi eld is left with the default (000000), the fi rst time
the downloading software connects with the Control Panel,
the fi eld will be fi lled with the software's CSID.
Q-49
Select programming mode entry reports to CS (0-1)
and
DEFAULT: Disabled (0)
A report can be sent to the Central Station any time installer programming mode
is entered and exited.
• The default (0) prevents reporting programming mode entry and exit.
• To report programming mode entry and exit, select enabled (1).
✓ NOTE: This report can only be sent through the telephone
dialer. It is not supported through the GSM radio.
Q-50
Select trouble reports to CS (0-1)
DEFAULT: Enabled (1)
Trouble reports can be sent to the Central Station when any sensor trouble
condition occurs.
• The default (1) allows reporting sensor trouble conditions.
• To not report sensor trouble conditions, select disabled (0).
✓ NOTE: This setting does not affect trouble reports caused by Control
Panel conditions, only trouble reports caused by sensors.
Q-51
Select manual bypass reports to CS (0-1)
DEFAULT: Disabled (0)
Manual bypass reports can be sent to the Central Station when any sensor has
been manually bypassed by the user.
• The default (0) prevents sending manual bypass reports.
• To allow sending manual bypass reports, select enabled (1).