Enter RF sensor (#) serial number (7 digits)
DEFAULT: 0000000
RF sensor serial numbers can be manually entered or learned from the sensor.
• For manual entry, enter the sensor number that was logged for the sensor
being programmed. Use the SHIFT button to access alpha characters.
• For automatic entry, press SHIFT, then press LEARN. The
Control Panel will wait for a sensor transmission. Trigger
the sensor being programmed and the Control Panel will
beep four times and learn the sensor's serial number.
If the sensor being learned is already in memory, the Control Panel will display a
sensor learning failure screen when the programming changes are being saved.
For certain sensors with more than two loops, the tamper switch must be used to
send a signal to the Control Panel during sensor learning. First press of tamper
switch will learn as Loop #1, the second press of tamper switch will learn as
Loop #2, the third press of tamper switch will learn as Loop #3. Wait 15 seconds
between each press of the tamper switch. The programmed loop number of
the sensor in the Control Panel may need changing to suit the operation of the
device. See the Installation Instructions of the sensor for details.
Select RF sensor (#) equipment age (0-1)
DEFAULT: New (0)
The Control Panel can be used with new or existing RF sensors.
• If this RF sensor is new for the installation, leave the default of new (0).
• If this RF sensor is already installed, select existing (1).
✓ NOTE: If the RF sensor has more than one loop and is being
programmed into multiple sensor numbers to support the loops,
set only one loop as "new" and the other loops as "existing". This
will prevent incorrect inventory of the installed sensors.
Select RF sensor (#) loop number (1-3)
DEFAULT: Varies with sensor model selected
2GIG-DW10 door/window sensors have two inputs: an internal magnetic contact
and an external normally closed hardwired input. Either or both sensor inputs can
be used. Some sensors have three loop inputs.
When using both the internal magnetic contact AND the external input,
THE MAGNETIC CONTACT AND THE EXTERNAL CONTACT NEED TO
BE ASSIGNED A DIFFERENT RF SENSOR NUMBER. BOTH SENSOR
NUMBERS WILL SHARE THE SAME SENSOR SERIAL NUMBER.
• When programming the sensor to use the built-in
magnetic contact, set the loop number to (2).
• When programming the sensor to use its hardwired
input, set the loop number as (1).
• When programming a 3-loop sensor to use an
additional input, set the loop number as (3).
• When entering the sensor number for the sensor's loop two
or three, the PASTE button can be used to recall the last
programmed sensor's serial number. (The sensor number
will be fi lled in automatically if LEARN is used.)
Select RF sensor (#) dialer delay (0-1)
DEFAULT: Enabled (1)
(Required SIA CP-01 Default)
RF sensors can trigger the communicator immediately or after a delay. The delay
time is set by the abort window dialer delay programming question Q-35 (the
default delay is 30 seconds).
• The default (1) causes delayed dialing for this RF sensor number.
• For immediate dialing for this RF sensor number, select disabled (0).
✓ NOTE: This setting for CO and smoke detectors is automatically set to
disabled (0), and this sub-question is skipped for these sensor types.
✓ NOTE: This default can be changed without affecting SIA CP-01 compliance.
Installer Programming
Construct RF sensor (#) voice descriptor
DEFAULT: No default
The voice descriptors are the words the Control Panel will announce for this RF
sensor if this sensor is programmed for voice annunciation. Up to fi ve words are
allowed.
• Press INSERT to place a word from the vocabulary into the data entry fi eld.
• Use the ← or → arrows to scroll through the words, or enter the
word's 3-digit index number (see vocabulary table on Page 19).
• Press INSERT again for the next word. Up to fi ve words are allowed.
• To move between words, press the FWD and BACK buttons.
• To remove a word, press DELETE.
Select RF sensor (#) reports (0-1)
DEFAULT: Enabled (1)
RF sensors can trigger a report to the Central Station or not.
• The default (1) enables reporting for this RF sensor number.
• To prevent reporting for this RF sensor number, select disabled (0).
Select RF sensor (#) supervised (0-1)
DEFAULT: Enabled (1)
When a sensor is set to supervised, the Control Panel will expect regular timed
signals from this sensor or else a sensor supervisory trouble alert will occur.
• The default (1) allows supervision for this RF sensor.
• To turn off supervision for this RF sensor, select disabled (0).
✓ NOTE: Portable sensors such as panic buttons should not be set as
supervised if the sensor will be removed from the premises at times.
Select RF sensor (#) chime (0-5)
DEFAULT: Disabled (0)
Each RF sensor can be set to sound a "ding-dong" chime and/or sound its voice
descriptor when the sensor is triggered. This step determines the initial setting
for the sensor. The end user can change the chime setting for sensors using
CHIME SETUP in the User Toolbox.
• The default (0) disables the chime for this RF sensor.
• If a chime and/or voice is required for this RF sensor,
choose one of the other chime options:
RF SENSOR CHIME
(0) disabled
(1) voice only
(2) ding-dong with voice #1
(3) ding-dong #2
(4) ding-dong with voice #2
(5) ding-dong #1
(6) ding-ding
(7) ding-ding with voice
(8) ding-dong #3
(9) ding-dong with voice #3
(10) chime #1
(11) chime #1 with voice #1
(12) chime #2
(13) chime #2 with voice #2
23